  1. Square D S133A Micrologic 5.0 Trip Unit w/LSI Functions

    square d micrologic trip unit

  2. Square D S133A Micrologic 5.0 Trip Unit w/LSI Functions

    square d micrologic trip unit

  3. NEW Square D S143A Micrologic 5.0 A Trip Unit PowerPact Breaker 33072

    square d micrologic trip unit

  4. Square D S133A Micrologic 5.0 Trip Unit w/LSI Functions

    square d micrologic trip unit

  5. Square D S133A Micrologic 5.0 Trip Unit w/LSI Functions

    square d micrologic trip unit

  6. SQUARE D S144A : CIRCUIT BREAKER MICROLOGIC TRIP UNIT

    square d micrologic trip unit

VIDEO

  1. Multidrop Microplate Dispensers

COMMENTS

  1. Micrologic Trip Units

    Part of PacT Series. All Micrologic trip units provide impeccable, electronic circuit protection with adjustable protection settings for maximum system coordination and flexibility. Sophisticated functionality, such as energy and power quality metering capabilities, is integrated in the more advanced trip units.

  2. MicroLogic ™ Electronic Trip Systems

    The MicroLogic H trip unit provides additional sampling of the waveforms to measure and provide waveform capture of harmonic distortion to the 31st harmonic. MasterPact universal power circuit breakers use MicroLogic electronic trip systems to sense overcurrents and trip the circuit breaker. The MicroLogic basic trip unit is standard and all ...

  3. MicroLogic 5.0P and 6.0P Electronic Trip Units User Guide

    MicroLogic 5.0P and 6.0P Electronic Trip Units User Guide . This instruction bulletin provides information on display navigation, trip unit configuration, operation, and trip unit, rating plug, and battery replacements for Micrologic™ 5.0P and 6.0P Electronic Trip Units.

  4. Range of Micrologic Trip Units

    Micrologic trip units are used on the Compact NSX circuit breakers. The range of Micrologic trip units consists of several families of electronic trip unit: o Micrologic 1, 2, trip units and Micrologic Vigi 4 trip units without display. o Micrologic 5, 6, trip units and Micrologic Vigi 7 trip units with display. A TM-D, TM-G, or MA trip unit.

  5. Description of the Micrologic 5 and 6 Trip Units

    Test Port. Micrologic trip units feature a test port specifically for maintenance actions. Use the test port to: o Connect a pocket battery for local testing of the Micrologic trip unit. o Connect the USB maintenance interface for testing, setting the Micrologic trip unit, and for installation diagnostics. For more information, refer to Compact NSX - Circuit Breakers and Switch-Disconnectors ...

  6. PDF Moulded Case Circuit Breaker MICROLOGIC Series B Trip Systems Features

    The MICROLOGIC Trip System can be either Standard-function or Full-function. Both trip systems provide adjust-able tripping functions and characteristics using true root-mean-square (rms) current sensing. The sensing system on an electronic trip moulded case cir-cuit breaker responds to the flow of current trough the circuit breaker.

  7. MicroLogic ™ DC1.0 Trip Unit

    The MicroLogic DC1.0 trip unit: is associated with sensors with instantaneous trip values. has two types: — fixed instantaneous trip — adjustable instantaneous trip, with trip values that can be adjusted on the front of the circuit breaker. Fixed and adjustable trip units have: has an instantaneous protection with no time delay settings.

  8. PowerPact P- and R-Frame Trip Units

    MicroLogic (Standard) 3.0 and 5.0 Trip Units. PowerPacT™ P- and R-frame molded case circuit breakers may be specified with any of the following MicroLogic Electronic Trip Units. True RMS sensing. LI, LSI trip configurations. Field-interchangeable long-time rating plugs. LED long-time pickup indication. Test kits available.

  9. Square D S131A Micrologic 3.0 Breaker Trip Unit

    Square D Micrologic 3.0 Breaker Trip Unit, Micrologic 3.0 LI Protection Field Installable, M/P/R/NT/NW, For Use with: Class 0216 PowerPact M, P and R-Frame, Compact NS630b, NS3200 and Masterpact NT/NW Universal Power Circuit Breaker. Additional Description: SQD -S131A CIRCUIT BREAKER MICROLOGIC TRIP UNIT TRIP UNIT.

  10. MicroLogic Electronic Trip Units Technical Literature

    MicroLogic™ 5.0P and 6.0P Electronic Trip Units - Instruction Bulletin.

  11. Micrologic Trip Unit Power Supply

    To provide a power supply to the Micrologic 5 or 6 trip unit when the load is below 20% of the rated current In, and maintain the full functioning of the Micrologic trip unit, one of the following optional power supplies can be used: o An external 24 Vdc power supply connected permanently to the Micrologic trip unit. o A power supply connected ...

  12. PDF Electronic Trip Molded Case Circuit Breakers (Class 0602 Catalog)

    For information on other types of molded case circuit breakers manufactured by Square D, See Thermal-Magnetic and Magnetic Only Molded Case Circuit Breakers Catalog 0601CT9101. Table 1. MICROLOGIC Trip Unit Features Standard-Function Circuit Breakers Full-Function Circuit Breakers d e t a r % 0 •8 • True root-mean-square (rms) sensing

  13. PowerPact H-, J-, and L-Frame Trip Units

    MicroLogic Trip Units [1] MicroLogic Standard 3.2/3.3 Trip Units. PowerPacT™ H-, J-, and L-frame molded case circuit breakers may be specified with any of the following MicroLogic Electronic Trip Units. MicroLogic Ammeter 5.2A/5.3A/6.2A/6.3A Trip Units. Includes all features listed for MicroLogic standard trip unit, as well as:

  14. Square D™ Micrologic 6.0 A Electronic LSIG Breaker Trip Unit, 6 A, P/R

    Square D S144A CIRCUIT BREAKER MICROLOGIC TRIP UNIT,6 A,6.0A,trip unit,Ammeter - LSIG,Micrologic. Menu Close . Contact Us {{::vm.contactUsPhone}} ... 1.50" X 1.50" Square Tube Profile - No Pre-Drilled Holes #9700; Tools. Tools. Access Hole Drill Jigs; Access Hole Drills; Anchor Fastener Counterbore Cutters;

  15. Square D Micrologic Trip Units

    The ETC-12 is a one-box fits all device in that the ETC-12 will replace a Micrologic control unit on any SED or SEF breaker frame size (800A, 1200A, 1600A, 2000A, 2500A, 3000A and 4000A). The ETC-12 seamlessly installs into the frame where the Micrologic is removed. The ETC-12 kit eliminates the need for pesky rating plugs.

  16. Micrologic Trip Units

    Micrologic Trip Units Control Units for PowerPact™ P, R, and Masterpact NT, NW. Part of PacT Series. Provide impeccable, electronic circuit protection with adjustable protection settings for maximum system coordination and flexibility. Sophisticated functionality, such as energy and power quality metering capabilities, is integrated in the ...

  17. MicroLogic™ Trip Unit Accessories

    MicroLogic P/H Trip Unit Cover, opaque gray. S47067. Trip Unit Seal (6 pieces) for compliance with NEC 240.6 (c) H/J/L/P/R. MICROTUSEAL. 12-pin Trip Unit Connector for NT/NW MasterPacT Circuit Breakers. P/R. S33101. 12-pin Trip Unit Connector for P- and R- Frame Circuit Breakers.

  18. Micrologic X Control Unit

    Micrologic X Control Unit. ... Trip Coil Supervision (ANSI 74) Lock-Out Function (ANSI 86) Overcurrent Trip Indication (ANSI 94) ... Ecoreach, EnerLin'X, Masterpact, Micrologic, Phaseo, PowerPact, PowerView and Square D are trademarks and the property of Schneider Electric SE, its subsidiaries and affiliated companies. All other trademarks ...