Does Your RCD Keep Tripping? Here’s How To Fix It…

  • Written By Complete Electricians
  • Get Free Electrical Advice

Are you fed up of times when your RCD keeps tripping for no apparent reason and shutting the electricity off in your house? Perhaps you’ve noticed that even though you’ve replaced the faulty component, it’s still tripping again and again. Why does this happen and what should you do about it?

This article will explore the different reasons why your RCD could trip, how you can prevent it from happening in the first place, and finally what actions you could take when the RCD trips.

What is an RCD?

Residual current device (RCD) is a safety device designed to switch off the power if there is a fault, acting as a trip switch. RCDs go beyond the safety levels offered by regular fuses and circuit breakers. An RCD is usually located in the fuse box (consumer unit). It might also be located between the circuit breaker and power sockets.

An RCD usually goes on the supply side of the equipment it protects, often inside a fuse box or on a distribution board. Some equipment may also have an RCD built into the plug. There are different types of RCDs that can serve various requirements.

RCDs generally work by monitoring the current flow in a lower voltage circuit. If they detect an issue with the current flow they shut off the power to the entire system, which prevents electrocution or severe injuries.

It makes sure that electricity will not flow to your home or business in the event of a fault, such as a short circuit. In simple terms, the RCD acts as a failsafe device and can be a lifesaver.

RCD keep tripping

Why does the RCD keep tripping?

There are many reasons why your RCD can keep tripping, and in this section, we will explore some of the more common causes for it. It is important that you pay close attention to this section especially prior to electrical rewiring as this will help address most of the issues at the forefront.

Faulty Appliance

A faulty appliance is one of the main causes why RCD keeps tripping. Technically, RCDs are designed to protect against electrical circuit faults from faulty appliances. If an RCD trips, it has done its job and removed the faulty electrical circuit from the power network which could potentially cause a fire. In most cases, this will be caused by appliances that have been poorly installed or maintained.

Incorrect RCD Current Rating Used

Each Residual Current Device is designed to trip when the current flowing through it exceeds a certain value. If the RCD’s rated value is too low, it will trip unnecessarily. You may find that your RCD is tripping repeatedly. This could indicate that it has the wrong rated current and should be replaced with one of the correct rating.

All RCDs should trip when the current exceeds its rating. A sign of an under-rated RCD is one that trips repeatedly, particularly on small overloads.

Low-Quality RCD

A low-quality RCD is a common cause of premature tripping. A true RCD will reset itself within a few minutes. It should never trip while it is resetting. Good quality RCDs should be able to withstand the current that passes through them during a reset continuously for at least an hour without overheating.

Accurate tripping is a great feature of RCD’s. It means that they are working correctly and if anything gets in the way such as a fault or a blockage it can trip quickly and easily. A low quality RCD will not be able to detect correctly and trips over time.

Fridge/Freezers Cooling Down

When your fridge or freezer begins to cool down, the motor inside it increases its work rate. This can cause power spikes, even when plugged into an RCD protected power point.

An RCD can react if there is a sudden rise in electrical current use or leakage current, due to the contents of your refrigerator or freezer thawing out.

Occasionally, a poorly connected appliance can cause a spike in electricity supply. If this happens, the RCD will trip and reset as it is designed to do. Electricity supply should return to normal shortly afterwards.

Moisture in Electrical Sockets

Moisture in outside electrical boxes and sockets can cause a trip by the RCD. It is vital that you detect moisture in your socket box early on. Exterior electrical terminal boxes and outlets should be periodically checked for moisture; signs of moisture may include weather-sealed cases that have deteriorated and/or reset switches that trip randomly.

Use of Older Washing Machines/Dryers or Motors/Pumps

Spikes can also be the result of poorly maintained or incorrectly connected equipment such as older electrical appliances, such as washing machines and dryers, which can cause the power to surge. With motors and pumps, if there is a correlation between the frequency/time of surges and use of an appliance, then it is most likely that that appliance was causing the RCD trip.

This trips when there is a sudden spike of electricity that can cause injury or damage. These spikes can be caused by lightning strikes, electrical faults, power tools, appliances with motors or pumps, old washing machines and dryers and so on.

Issues with Central Heating Systems

A faulty component in your central heating could cause RCD trips. An RCD trip is often triggered when the faulty part turns on and off repeatedly, which may lead to false alarms. Permanent damage could be caused to electrical equipment if your home suffers frequent or prolonged RCD trips due to a faulty component.

Water in Wiring

Maintaining a high standard of electrical safety is crucial. When the resistance of a piece of wiring exceeds a certain level electricity will travel via a shortcut. If this path happens to include water or dampness, your RCD will trip to protect you from the risk of electrocution, which is probably why the RCD keeps tripping.

In many cases, residents and vacationers alike fail to properly care for their recreational vehicles and water intrusion can occur. Due to this, there is a possibility of RCD trips.

Fixing a Tripping RCD

Having looked at the various causes on why RCD keeps tripping, let’s expand further on each of them to understand how we could fix a RCD that keeps tripping.

How to fix faulty appliance from tripping

If you suspect that a faulty appliance may be causing your RCD to trip, try unplugging every electrical appliance in your home and checking whether your RCD resets correctly. If it does, plug in each appliance one by one and reset your RCD as you plug in each item.

If suddenly the RCD starts tripping again shortly after plugging in one item in particular, then you’ve likely identified the specific cause.

How to fix incorrect RCD Rating used

If your circuit breaker is rated beyond the requirements of the home’s electrical system, it may need to be replaced. Professional electricians can visit homes for visual inspection to determine whether or not the RCD needs to be replaced.

How to fix low-quality RCD

It is best for a trained electrician to replace low quality RCD. In most cases, this kind of professional installation is necessary. It can even be dangerous to replace the RCD yourself – this is why you should hire a reputable contractor to replace it.

How to fix Fridge/Freezers from tripping

It might be possible that the motor cooling the fridge or freezer is broken. A professional may recommend having it replaced or rerouting the wires connected to the appliance to prevent tripping. If the motor is tripping, it would be best to call a professional. You can get it replaced or reroute the wiring to prevent RCD trips.

Fixing the RCD trips caused by moisture in Electrical Sockets

The moisture present outside electrical boxes or sockets can be risky when it comes to the safety of the property.  When you encounter an electrical problem due to moisture present in outside electrical boxes or sockets, it is important to first turn off the power supply completely before drying the electrical boxes or sockets. If the weather seals have been destroyed beyond repair, it is recommended that you have them replaced.

Fixing trips from older washers and motors

A licensed electrician  can take a look at your washer or dryer if you believe that one of these devices is the cause. If you are right, they may suggest having a particular part repaired or replaced, depending on the severity of the issue.

Fixing RCD trips caused by central heating issues

If you have a RCD tripping due to central heating problems, call an electrician to assess your home’s wiring. The RCD will trip if the correct electrical current cannot be delivered to the part being used. Depending on the scale of the problem, you might need to replace old wiring or have an electrician do it for you.

Alternatively, you can get in touch with a professional electrician who will be able to give suggestions as to how you can avoid similar issues in the future, such as repairing now and replacing in the future.

How to Fix RCD Trips Caused by Water in Wiring

The right heating and ventilating systems are vital to ensuring that moisture is not present in your home’s wiring. In other words, improperly ventilated or heated homes can cause water to damage electrical wiring. Heating and ventilation systems can be combined with humidity control devices, such as a hygrostat (humidistat) or a hygrotherm, to regulate the moisture levels in a home.

How to remove an RCD from your fusebox

In order to remove the RCD from the fuse box, you must first ensure that all electrical load has been disconnected from the RCD. Once all loads have been disconnected, you will notice a small tab on the front of the RCD. Take a flat bladed screwdriver and insert it into the slot on the back of the RCD. Next, firmly pull down on the slot as you pull the RCD away from the fuse box.

In most cases, the RCD is located in the fuse box. The RCD switch may be labelled “RCD.” Alternatively, you may locate a “T” or “Test” above it. Make sure the power to the circuit is switched off before taking out the screws that attach the RCD to the fuse box.

Replacing an RCD in a fusebox

To replace an RCD, you will first need to remove it using the steps described above. Once the RCD is removed, another can be put in place by completing the removal steps in reverse. However, a new RCD will also need to undergo various tests. While replacing an RCD can be done DIY, unless you are well-studied and highly competent in the area, you should hire an electrician. This is because there are multiple aspects to correctly replacing an RCD. 

The cost of replacing an RCD can range between between £30 and £70 including both installation and supply costs. An RCD itself will likely cost between £10 and £40.

How to prevent an RCD from tripping?

To prevent RCD trips, you should conduct regular appliance maintenance on your RCD, keeping it free from dust and damage. Checking that appliances are rated for the correct mains voltage can help determine if the appliance is faulty.

It’s also worth checking that your equipment has a current rating that is appropriate for the amount of power being drawn from it.

To reduce the risk of an RCD tripping due to electric moisture, ensure that electrical wiring is adequately ventilated, ensuring that there is no moisture present in sockets or electrical boxes. The power must be turned off before inspecting sockets/boxes. Installing a device to control humidity levels, ventilation fans and good sockets will keep you safe at home.

Consequences of not fixing an RCD

If your RCD keeps tripping, it’s important that you pay close attention to it as it can otherwise lead to many hazards such as the risk of fire and electrocution. An RCD which is continually tripping may already be faulty or low-quality to begin with but either way repeated tripping can cause the RCD to deteriorate over time.

Depending on the model, RCDs may be used to protect against electrical fires. A faulty or broken RCD can make a home more vulnerable to fire and lead to unnecessary and dangerous conditions.

Electrical Malfunctions

If an RCD is unable to trip, it may become damaged over time, leading to electrical issues. Damaged circuits can be a fire hazard, increasing the risk of electrocution, damage to the appliances and wear and tear on the wiring.

You could be putting yourself and your family at risk if you have an electric issue, but don’t realise. A non-functioning or faulty appliance is not always obvious, which means you could become accident-prone with no RCD protection in place.

Final thoughts

From the above discussion, it can be understood that it’s important that you continuously watch if the RCD is in a good condition. Additionally, you would need to ensure that they are well maintained so you can prevent any hazardous and harmful risks such as fire and electrocution. You would also need to ensure that your property follows the local regulations.

If all of this seems overwhelming to you, you can always contact your local electrician to help fix any issues with an RCD that keeps tripping. 

South West Electrical Contractors

Complete Connectrix Ltd are fully qualified electrical contractors providing electrical packages for contractors, house builders, architects, local authorities, businesses and private clients across South West England.

trip switch too sensitive

Contact Complete Connectrix Ltd

  • Unit Z, Creech Business Park, Creech St Michael, Taunton, Somerset, TA3 5PX
  • Email: [email protected]
  • Office: 01823 589449
  • Opening Hours: Monday to Friday: 8.30am - 5.30pm

Important Links

  • Our Services
  • Residential Electrical
  • Commercial Electrical
  • Customer Reviews
  • Case Studies

Our Locations

  • Privacy Policy

MARKETING BY SCALEYOURTRADE.COM

NH Electrical Ltd Logo

What to do if your RCD trips

Consumer Unit

Have you been left in the dark? Has your consumer unit / RCD tripped? This could be happening for several reasons but usually there’s a quick an easy fix. Through a process of elimination, you can work out what’s causing the problem and reset the trip switch yourself.

At NH Electrical we don’t want you to be left in the dark! By using the simple steps below you’ll never be stuck searching for candles when the lights go out again. Our quick guide will equip you with the knowledge you need to fix your consumer unit in no time at all.

Please do bear in mind though that while it is perfectly safe to touch your consumer unit, faulty electrics are very dangerous. If you are not confident in your ability to carry out electrical tasks, always seek the help of a fully qualified electrician.

How does a fuse work?

Before we talk you through what to do if your consumer unit trips out, let’s quickly go over the purpose of a fuse.

Fuses are important components, used in electrical circuits as a safety measure to protect you and your home. If there is a fault in the electrics or excessive current flow, the fuse will heat up and melt which will break the circuit. This ensures that both you and those living in your home remain safe.

Although some older properties will still have the old traditional consumer units with fuse wire (If you do still have the old consumer unit you should look to replacing it), today you’re more likely to have a modern consumer unit installed. This will contain trip switches or circuit breakers. The main advantage of having a modern consumer unit is that you will not have to replace the fuse wire, every time it blows. If your consumer unit trips, it’s a matter of flicking a fuse switch to reset it, which is far more easier than the traditional method.

Locating the consumer unit in your house

It’s important that you know where your consumer unit is located within your house, as you never know when you may need to turn the electricity off in an emergency. It should be found in an easily accessible place so that you can locate it, even if the lights go out.

Your consumer unit will contain three types of components:

  • The main switch – Turns off the electricity supply to your home. Useful to remember in an emergency.
  • Fuse switches (or circuit breakers) – Switches that trip to protect the appliances in your home, if there’s a fault in the circuit. They provide more accurate protection than traditional wire fuses.
  • RCDs (Residual Current Devices) – Switches that will trip and turn off the electricity if the circuit they manage is considered dangerous. They are designed to prevent electrical fires and electrocution.

Dealing with a tripped fuse switch

If your lights have gone out or your appliances have stopped working all of a sudden it is likely that you have tripped a fuse switch. To begin to resolve the problem, you’ll need to first locate the main consumer unit in your home and check to see if all of the trip switches are on.

If you are not sure whether ‘on’ means consumer unit switches up or down? See if the majority are up or down and you’ll have your answer. It’s most likely to be the up position for ‘on’ and the down position if they’ve tripped.

If any switches are down then flicked them back into the up position to turn them back on. If it isn’t an electric trip switch that has moved, it’s probably one of your RCD switches. Make sure they’re turned on too. Once this is done, everything should be back on and in working order.

  • Find your consumer unit and lift the front cover
  • Check if all of the trip switches are on
  • Switch on any switches that have tripped
  • Check that the RCD switches are switched on too

Why won’t the trip switch reset?

There is a possibility that your fuse switch may continue to trip even after you have reset it. If this happens it is likely to be a problem with one of your appliances or sockets. To find out if it is this try the following

  • Unplug all of your appliances and try resetting the fuse switch.
  • Once reset, plug your appliances back in one at a time and switch them back on.
  • If the switch trips again, you’ll know it’s the last appliance that you plugged in and switched on.
  • Turn off and unplug the appliance, before resetting the switch.
  • Do not attempt to plug the appliance back in – it’s likely there’s a fault with its wiring that will need replacing.

You don’t necessarily need to throw the appliance away – the issue could be easy to fix. However, faulty appliances can be dangerous, so it’s best to get in contact with an qualified electrician.

Why has the main fuse tripped again?

Although there’s usually a simple explanation of why your circuit breakers or RCDs are tripping, if it’s the main switch, it can be a little more complex. It could mean there’s a problem with the consumer unit itself. If this is the case, you’ll need assistance from a fully qualified electrician. We do not recommend trying to fix the consumer unit yourself.

Why has my consumer unit tripped?

If you’re lucky, your electric consumer unit will have labels under each switch telling you which circuit they control e.g. lights or sockets. This makes it much easier to identify where the problem is located and will save you having to turn off every light and unplug every device in your home to work out what is causing the tripping.

As a rule of thumb, it is likely to be the last appliance or light fixture you used that is causing the trip. Trip switches are very sensitive for your safety so as soon as there’s an issue, they’ll kick into action and cut the power.

If your box isn’t labelled or you are struggling to narrow down the problem, the only solution is to unplug every device in your home, reset the switch and plug them back in one at a time. It’s time-consuming but should find the root of your problem.

Overloading circuits

If all of your appliances are in working order then they are unlikely to affect your trip switch. This means it could be down to you overloading your circuits. This means there is too many electrical appliances using this switch at one time. If you’re boiling your kettle, charging your phone, using your toaster, watching TV and running your dishwasher all on one circuit, you could be overloading it, resulting in your electricity not working the way it should. Your consumer unit wont allow you to overload a circuit by using too many appliances in one socket as its dangerous and therefore will trip.

Rather get an expert to do it?

If you are not confident in doing this yourself or would just simply prefer an expert to carry out the fault finding and making the electrics safe again then please contact us and one of our fully qualified electricians is on hand to help 24 hours a day, 7 days a week.

Share This Article

Related posts.

How Security Lighting Can Help to Protect your Home

How Security Lighting Can Help to Protect your Home

‘Tis The Season To Be Safe! Christmas Lights Safety Guide

‘Tis The Season To Be Safe! Christmas Lights Safety Guide

Benefits of PAT Testing

Benefits of PAT Testing

What are The Advantages of Led Lights?

What are The Advantages of Led Lights?

5 Benefits of Hiring Reputable & Qualified Electricians

5 Benefits of Hiring Reputable & Qualified Electricians

thumbnail_SES_Final_rgb_no-Background.png

01727 238 999

[email protected].

google-guaranteed-badge.png

  • Specialist Electrical Solution Ltd
  • Dec 24, 2022

What To Do If Your RCD Keeps Tripping?

Updated: Jan 3, 2023

If you are experiencing an issue with your Residual Current Device (RCD) tripping, you are probably wondering what to do next. An RCD is a safety device that is designed to protect you and your home from electric shocks and electrical fires, so it is important to take any warning signs seriously. In this blog post, we will discuss what to do if your RCD keeps tripping and how to work out the cause of the problem. We will look at the different types of RCDs and the most common causes of tripping. We will also look at how to diagnose and fix the problem yourself and when it is best to call a professional electrician. By the end of the post, you should have a better understanding of your RCD and how to troubleshoot any issues.

Inspect the circuit breaker panel

One of the first things you should do if your RCD keeps tripping is to inspect the circuit breaker panel. Make sure that all the switches are in the correct position, and that none of the breakers are tripped. If you do find that a breaker is tripped, try to reset it. If the breaker trips again, it could be a sign of a bigger problem that needs to be addressed by a professional electrician.

Check for faulty appliances

The second step to take if your RCD keeps tripping is to check for faulty appliances. Faulty appliances can draw more current than they should, causing the RCD to trip. Check to make sure all your appliances are in good working order, and if they aren’t, have them serviced or replaced. Also make sure that none of your appliances are overloaded. If you have too many appliances plugged into one outlet, the amount of current drawn could be too high and cause the RCD to trip.

Look for damaged circuits

One of the most common causes of a tripping RCD is a damaged or faulty circuit. If you notice your RCD tripping frequently, it’s important to check all of the circuits in your fuse box for any signs of damage. Signs of a damaged circuit include frayed wires, smoke, sparks, or a burning smell. If you notice any of these signs, it’s important to switch off the power at the main switch and call a qualified electrician to repair or replace the circuit.

Test the RCD

The fourth step in troubleshooting your RCD is to test the RCD itself. Start by unplugging all the appliances connected to the RCD. If the RCD trips again, you can be sure the problem is with the RCD itself. To test if it is faulty, you should use a multimeter to perform a continuity test. Set the multimeter to its lowest range and make sure it is set to measure resistance. Connect one lead of the multimeter to the live side of the RCD and the other to the neutral side. If the resistance is not zero, it means your RCD is faulty and needs to be replaced.

Contact a qualified electrician for assistance

After trying to reset and troubleshoot the problem with your RCD, the next step is to contact a qualified electrician for assistance. An electrician will be able to examine the wiring and circuits in your home and identify any underlying issues that might be causing your RCD to trip. They can also provide advice on how to remedy the situation, such as replacing faulty wiring or even installing a new RCD.

Before you attempt to troubleshoot your RCD tripping, it’s important to ensure that your RCD is working properly. If you’re unsure, it’s best to call a professional electrician for help. Once you’ve identified the cause of your RCD tripping, you can take the necessary steps to fix the issue, ensuring that your home is safe from electrical hazards. Contact us for a quote.

Recent Posts

Reviving Warmth: Radiant Heating Upgrade at St. Bartholomew Church

How Long Does It Take To Install Solar Panels

How Much Does It Cost To Install A Solar Panel

Top Coventry Electricians Logo

Electricians With A Spark

Understanding RCD Tripping

Understanding RCD Tripping: Causes, Fixes, and Prevention

  • December 3, 2023
  • , RCD's

What Is An RCD (Residual Current Device)?

An RCD, or residual current device, is a safety device found in modern electrical circuits. It detects faulty currents flowing through the circuit and quickly switches off the power if there is a risk of electrocution or fire. This helps prevent electric shocks and protects against electrical fires in the home.

Overview Of RCD Tripping: Understanding The Basics

RCD tripping occurs when the RCD detects a fault in the electrical circuit. This causes the RCD to immediately switch off the power to prevent harm. Some common triggers for RCD tripping include faulty appliances, overloaded circuits, damaged cables, and moisture ingression. While occasional nuisance tripping can occur, repeated RCD tripping indicates an electrical fault needs to be addressed. Identifying the root cause is key to fixing the issue.

I’ve written the first two subheadings per your instructions. Please let me know if you would like me to continue with the next two subheadings or if you have any feedback on the sections I’ve written so far. I’m happy to refine and improve the content before continuing.

trip switch too sensitive

Identifying The Causes Of RCD Tripping

There are several common causes of rcd tripping:, faulty appliances:.

One of the most frequent reasons an RCD trips is a faulty appliance, especially those with motors or heating elements. If there is damaged wiring inside the appliance, small leakage currents can flow to earth, triggering the RCD.

Incorrect RCD Current Rating:

If the current rating of the RCD does not match the total load on the circuit, it may trip out unexpectedly. An electrician needs to calculate and install the properly rated RCD.

Quality of RCD:

Lower quality or older RCDs can sometimes nuisance trip, while top brands tend to be more reliable. Upgrading to a quality RCD may help resolve tripping issues.

Specific Appliances and Their Influence:

Some types of appliances, like refrigerators, freezers, motors and pumps are more prone to causing RCD tripping under certain conditions.

Environmental Factors:

Moisture, water or dampness entering electrical boxes or wiring can allow small earth leakage currents to flow, triggering the RCD. Fixing water ingress issues is key.

Solutions and Fixes For RCD Tripping

There are several systematic troubleshooting steps to address tripping RCD issues:

Identify and inspect the offending circuit and appliances. Unplug appliances one-by-one to isolate the problem device.

Check for water damage, corrosion, loose connections or faulty cabling supplying the circuit. These can allow leak currents.

Verify the RCD current rating is appropriately sized for the circuit. An electrician may need to install a higher rated RCD if overloaded.

Replace any damaged devices, cables or sockets contributing to the fault. Upgrade to quality electrical components.

For recurring tripping RCD with no obvious cause, consider replacing the RCD completely in case it is faulty.

For further information on Fault Finding RCD tripping, N Bundy Electrical have a created a fantastic video which provides a great insight in trying to find a tripping RCD.

Preventative Measures and Maintenance

How to prevent rcd from tripping.

Some tips to help prevent nuisance a faulty RCD tripping include:

Regularly inspect appliances and cables for damage. Replace old, faulty electrical equipment. Address any water damage issues quickly to prevent electrical faults developing. Ensure circuits are not chronically overloaded by spreading appliances over separate circuits. Have an electrician periodically verify RCD ratings match the circuit load. Test RCDs monthly by pressing the test button to confirm proper operation.

Regular Maintenance Tips for Electrical Systems Good maintenance habits help minimise tripping RCD:

Annually inspect the electrical panel, circuits and wiring for signs of loose , damaged or burnt connections. Check sockets and switches for cracks or moisture damage which can allow currents to leak. Ensure outdoor wiring and electrics are suitably rated and protected from weathering. Have a qualified electrician inspect and service electrical systems every 3-5 years. Update aging electrical panels, fuseboards and circuit wiring to meet current safety codes. Proactive maintenance helps avoid electrical faults that contribute to RCD tripping over time.

Advanced Troubleshooting and Replacements

Removing and Replacing an RCD from Your Fuse box If an RCD is suspected to be faulty and repeatedly tripping, an electrician can remove and replace it from the fusebox:

Fully disconnect the power supply at the main circuit breaker before accessing the fuse box. Unscrew any retaining clips or screws securing the RCD unit in place from the fusebox panel. Disconnect and label the incoming and outgoing wires connected to the RCD terminals. Before installing the new unit, verify its current rating matches the circuit’s requirements. Securely fasten all terminals and ensure polarity is correct before restoring power. Press the test button after powering up to validate correct installation.

Understanding RCD vs. MCB: Differences and Implications RCDs and MCBs (miniature circuit breakers) both cut power in a tripped circuit but function differently:

RCD detects small earth leakage currents and cuts power quickly to prevent electrical shocks. MCBs trip from overloads and short circuits to halt high unsafe currents from flowing. For safety critical applications, RCDs must be used to defend against electrocution risk. MCBs cannot provide equivalent protection on their own.

Safety & Consequences

The Dangers of Ignoring RCD Issues

Ignoring recurring tripping RCD poses serious safety hazards. It leaves underlying electrical faults unaddressed that could turn into a fire or electric shock risk. Nuisance tripping can disrupt important appliances like fridges and freezers, leading to food spoilage. Elderly, sick or immobile occupants may have medical devices unexpectedly lose power, putting them at risk. RCD tripping should never be ignored or bypassed. Unresolved faults must be investigated by a qualified electrician.

trip switch too sensitive

Final Thoughts On RCD Tripping

In summary, RCDs are a critical electrical safety device that detect dangerous leakage currents and promptly cut power to prevent harm. Occasional nuisance RCD tripping does happen but recurring tripping signals an underlying electrical system fault exists.

Methodically troubleshooting the issue by checking appliances, electrical wiring, RCD specs and environmental factors helps narrow down the root cause. Addressing damaged devices, undersized RCD units or water ingress provides permanent solutions. For recurring unexplained RCD tripping, replacing the RCD itself often fixes the problem.

While a nuisance, RCD tripping is doing its job in protecting safety. So when those pesky devices do trigger, be sure to methodically track down the electrical fault!

Frequently Asked Questions about RCD's Tripping

How do you reset a tripping rcd.

Resetting tripped RCDs is straightforward:

Locate the tripped RCD switch in the electrical panel, which will be midway between on and off. Switch it fully to off, then back to on. Avoid quickly flicking it on-off-on to reset. If it trips again instantly, the electrical fault is still present and needs addressed by an electrician. The key is fixing the root electrical fault first before resetting the RCD.

How do you test an RCD for nuisance tripping?

Electricians can perform several tests to assess if an RCD is nuisance tripping:

Check if the RCD trips when large appliances turn on or off. If so, the unit is oversensitive. Time how long the RCD takes to trip when pressing the test button. It should trip quickly within 200ms. A delayed trip indicates a problem. Use a dedicated RCD tester that introduces a small ground fault and checks if the RCD properly trips without excessive delay. Monitor to see if the RCD trips randomly when the circuit is stable. Intermittent tripping points to a faulty device. If testing confirms nuisance, rapid replacement of the RCD often resolves the tripping.

Can a loose connection cause RCD to trip?

Yes, loose wiring connections absolutely can lead to RCD tripping. As vibrations occur over time, loose connections degrade and start to arc. This allows small leakage currents to flow to ground that the RCD detects, causing a trip. Any loose, damaged or corroded connections must be re-secured or replaced.

How do you find out what is tripping my electric?

Strategically unplugging devices on the tripped circuit helps isolate the problem load tripping the electricity. Start by shutting off higher wattage devices first. If the RCD holds steady after unplugging a particular appliance, this points to it likely causing the tripping. Targeted testing of that device and wiring using a multimeter can then check for electrical faults.

What would cause an RCD trips?

Faulty appliances, undersized RCD units, moisture in wiring, damaged cables and normal aging of electrical components can all cause RCDs to trip. Identifying the specific culprit component leading to the earth leakage current allows the issue to be addressed.

Why is my RCD tripping with nothing plugged in?

If an RCD trips on a faulty circuit with no appliances running, it likely indicates a damaged cable, socket or switch is allowing small leakage currents to flow to ground and trip the device. An electrician would need to systematically isolate the fault through testing.

Share this post

Cambridge Discount Electrical Logo

Nuisance RCD tripping – What causes it and how do I fix it?

trip switch too sensitive

Household electrical problems can be a major annoyance, but some pose an infinitely greater inconvenience than others. Perhaps the most common problem fault experienced by every homeowner is a tripped RCD.

We’ve all been there – we’ve just put the kettle on for a cup of tea before bed and suddenly the power snaps and we’re forced to shuffle around in the dark with our smartphones to find the RCD box (and it’s rarely in the most convenient place).

But if your RCD is tripping every couple of days (or even daily) and it’s become a genuine nuisance in your daily life, is there anything you can do to help the situation before calling someone in yet again? Let’s start with the basics.

Why is my RCD tripping?

Your RCD (residual current device) serves as your major protection against electric shock which is why it is now mandatory for all homes and businesses to have one installed. When your RCD trips what it thinks it’s doing is actually saving your life because it’s detected an electrical fault that could prove deadly if the circuit is not closed off completely.

Occasionally, an RCD can trip even when there is no fault to speak of (if there is a great surge in power, for example) but if it’s happening regularly then it’s most likely due to one of three causes:

Faulty equipment – As electrical equipment ages, it can become more unstable, particularly when used in tandem with other devices. If your RCD is constantly tripping when you use a specific appliance (whether it’s your washing machine, your toaster, or your blender) then it is most likely to be a fault with the equipment. So, rather than calling out an electrical engineer , simply replace the faulty item or get it fixed.

Bad wiring – This one is a lot more concerning. If you can’t see the RCD tripping being related to any specific appliance then it might be a problem with your wiring that needs some urgent attention.

If the wiring in your walls is faulty or frayed and has lost its insulation then it can cause a short circuit, resulting in an electric shock or even an electrical fire if there is no RCD installed to automatically break the circuit. If you suspect bad wiring in your property then you must immediately get in touch with your local electrical services provider and call out an electrician.

Ground fault – This refers to your RCD tripping to prevent an electrical current from making a connection with a grounded surface, which can prove fatal. This is in situations such as if a hairdryer falls into the bathtub, somebody puts a knife in the toaster, or somebody drills through a wall into active wiring.

How to fix nuisance trips?

If none of the above sounds like they apply to you, then you could have a nuisance trip problem. The problem with these so-called ‘ nuisance RCD trips ’ is that the cause can be quite difficult to figure out. That’s why we would always recommend calling out an electrician.

However, if it is something that happens constantly, even after the electrician has been out and given you the all-clear, then a good quality leakage clamp meter and some background knowledge can save a lot of time and frustration, not to mention your wallet.

Modern appliances and plug-in power supplies, by the nature of their design, generate low levels of leakage current, even when there’s no fault. This becomes a problem when there are several appliances connected to the same circuit and their leakage currents combined exceed the trip threshold of the RCD protecting the circuit. This causes the power to cut out unexpectedly, even when there is no actual problem to speak of.

To reduce nuisance RCD tripping that’s a result of cumulative leakage from appliances, the 18th Edition Wiring Regulations Guide includes specific maximum values for protective earth currents (Regulation 531.3.2). According to the guide: “The accumulation of circuit protector currents/earth leakage currents that are present during normal operating conditions shall not be more than 30% of the rated residual operating current of the RCD.”

This means that, for example, a current of just 30% of the residual operating current can cause a trip and when you consider the average operating current is around 30mA, that’s just around 9mA that can set it off, so to speak. Eve a hoe computer can generate a leakage current of up to around 3mA on its lonesome.

The only way to definitively ensure nuisance trips cease completely is to measure the leakage flowing using a leakage clamp metre for reliable results.

However, please be advised that when working on any electrical system, you must have access to the distribution board and the electricity must be switched off at all times.

Need a qualified electrician in Liverpool or the surrounding area? Call us now: 0151 440 2643

Local Electrical Group

How to Fix RCD Tripping: A Comprehensive Guide for Quick Solutions

Experiencing RCD tripping in your home or office can be a nuisance, but resolving the issue is important for safety reasons. RCD, or Residual Current Device, is a safety device that monitors electric circuits for any imbalance between the live and neutral conductors. When an imbalance is detected, the RCD quickly shuts off the power supply, preventing electrocution and reducing the risk of electrical fires.

To fix RCD tripping, it’s crucial to first understand what may be causing these disruptions. Common causes include faulty appliances, damaged wiring, and for older installations, natural wear and tear. By identifying the source of the problem, you can take appropriate steps to address it and prevent future occurrences.

Key Takeaways

  • Learn to identify the cause of RCD tripping for effective resolution.
  • Follow safety precautions while attempting to fix RCD tripping issues.
  • Regular maintenance and checks can help in preventing RCD trip disruptions.

Understanding RCD Tripping

Residual Current Devices (RCDs) are critical safety devices designed to protect you from electric shock and reduce the risk of electrical fires. However, RCDs can sometimes trip without an apparent cause, interrupting the power supply and leaving you wondering what went wrong. To effectively troubleshoot and fix RCD tripping issues, it’s essential to understand how these devices work and what might trigger them to trip.

trip switch too sensitive

An RCD constantly monitors the electrical current flowing through your circuits. It detects when there’s an imbalance in the current going in and coming out of a circuit, which may indicate a fault, such as a short circuit or a current leakage to the ground. If the RCD senses a dangerous fault, it quickly disconnects the power supply, preventing electric shocks and potential fires.

There are several reasons why an RCD might trip, including:

  • Overload: Connecting too many high-wattage devices to a single circuit can cause the circuit’s amperage to exceed its rating, leading the RCD to trip.
  • Short circuit: When a live wire touches a neutral or ground wire, a large current flows through the circuit, causing the RCD to initiate a safety intervention.
  • Ground fault: If a live wire comes in contact with a grounded surface (e.g., a damp floor or metal pipe), the electrical current can leak into the ground, creating an imbalance that triggers the RCD to trip.
  • Appliance faults: Damaged or faulty appliances, such as fridges, washing machines, and kettles, can cause the RCD to trip when plugged in.
  • Environmental factors: Moisture, dust, and corrosion can hinder the performance of electrical circuits, leading to RCD tripping.

To identify why your RCD is tripping, first, unplug all appliances and power off the circuit breakers for the affected circuit. With everything disconnected, try resetting the RCD. If it stays on, it suggests that the issue lies with an individual appliance or an overloaded circuit.

To pinpoint the specific cause, reconnect the appliances one at a time. When the problem appliance is plugged in, the RCD will trip again. At that point, you know you’ve identified the source of the issue. You can then either fix or replace the faulty device, resolving the RCD tripping problem. Should the RCD continue to trip with all appliances disconnected, consult a qualified electrician, as there may be a more complex issue with your electrical system.

Safety Precautions While Fixing RCD Tripping

Firstly, before attempting to fix RCD tripping, it is essential to switch off the main power supply . This ensures that you are not exposed to live electricity while working on the issue. Wear rubber sole shoes, gloves, and safety goggles if possible to minimise any risks.

Identify the cause of the RCD tripping before attempting any repairs. One common reason is an overloaded circuit. Check each appliance or device connected to the circuit and make sure it is within the recommended wattage for that circuit. Remove any devices that may exceed the limit to prevent further trips.

Never work alone when dealing with electrical issues. Having a partner nearby can be crucial in case of an emergency. They can call for help or provide assistance if needed. Make sure the person is aware of basic safety procedures and can assist effectively.

Test your RCD to ensure it is functioning correctly. Use a plug-in RCD tester, following the manufacturer’s instructions. This will indicate if the problem lies within the RCD itself or elsewhere in the electrical system. If the RCD is faulty, it is recommended to have it replaced by a professional.

Seek professional help if you are unsure about any aspect of fixing the RCD tripping issue. A qualified electrician is trained to handle various electrical problems, including RCD tripping. They can troubleshoot the problem and provide solutions quickly and safely.

Remember, prioritising safety precautions while fixing RCD tripping is crucial to prevent accidents or damage to electrical systems.

Identifying the Cause of RCD Tripping

Investigate circuit overloads.

Circuit overloads can sometimes cause your RCD to trip. To identify if this is the issue, first turn off all electrical devices connected to the circuit. After unplugging all devices, reset the RCD by pushing the switch back to the “on” position. Gradually reconnect each device, one by one, and observe if the RCD trips again. If it does, you may have identified an overloaded circuit. In this case, consider redistributing the load across different circuits or upgrading the circuit to handle a higher amperage.

Identify Faulty Devices

Faulty devices can also cause RCD tripping. To check for faulty devices, first isolate the circuit by unplugging all electrical devices connected to it. Reset the RCD, then reconnect each device one by one. After reconnecting a device, test it to see if it is functioning correctly. If the RCD trips when a specific device is connected and activated, that device may be faulty. Remove the faulty device from the circuit and consider having it repaired or replaced.

Examine Wiring Issues

Wiring issues, such as damaged cables or loose connections, might contribute to RCD tripping. To examine your electrical system for potential wiring problems, begin by visually inspecting your home’s wiring for any visible damage. Look for signs such as frayed or exposed wires, burnt marks, or loose connections. If you spot any of these issues, contact a qualified electrician to properly address the problem.

Additionally, be aware that some older homes may have outdated wiring that doesn’t meet modern safety standards. In this case, it is recommended to have a professional electrician inspect and potentially upgrade your home’s electrical system to ensure your safety and prevent RCD tripping issues. Remember, electrical work can be dangerous, so it’s essential to always consult a professional to handle these matters.

Methods to Fix RCD Tripping

Resetting the rcd.

Before addressing any other issues, first try resetting your RCD. Turn off all devices connected to the affected circuit and switch off the main power supply. Locate the RCD in your consumer unit and push the test button; this should cause the RCD to trip. To reset, push the switch back to its original position. If the issue persists, move on to the next solution.

Fixing Circuit Overlord

A circuit overlord occurs when too many devices draw power from the same circuit simultaneously. To fix this issue:

  • Identify the overloaded circuit : Check which devices are connected to the circuit and if they are all necessary.
  • Redistribute the load : Disconnect some devices and reconnect them to a different circuit to evenly distribute the load.
  • Upgrade your electrical system : If redistributing the load doesn’t work, consider upgrading your consumer unit to handle a higher electrical capacity.

Repairing Faulty Devices

Another cause of RCD tripping could be faulty devices. To identify and repair a faulty device:

  • Disconnect all devices : Unplug devices from the affected circuit.
  • Reset the RCD : Follow the reset process described in the “Resetting the RCD” section.
  • Reconnect devices one by one : As you reconnect each device, check if the RCD trips again. If it does, you’ve identified the faulty device.
  • Repair or replace the faulty device : Have the device repaired or replaced to prevent future RCD tripping.

Resolving Wiring Issues

Wiring issues like damaged insulation, loose connections, or water damage can all lead to RCD tripping. To resolve these issues:

  • Identify the problematic wires : Start by examining the wiring in the affected circuit for visible damage.
  • Disconnect power : Before handling the wiring, switch off the main power supply to avoid electrical hazards.
  • Fix or replace damaged wires : Repair or replace any damaged wires you find. If you’re uncertain or inexperienced, consult an electrician to ensure your safety.

By following these methods, you should be able to fix RCD tripping and keep your electrical system working effectively and safely. Remember to exercise caution and consult a professional if necessary.

Maintenance Tips to Prevent RCD Tripping

Regular maintenance of your electrical system is essential to prevent RCD tripping. By keeping your devices in good working order, you can minimise the likelihood of faults that may cause unnecessary trips. Here are some practical tips that you can follow to help ensure a safe and functional electrical system:

Inspect wiring and sockets : Regularly checking the condition of your wiring and sockets helps you identify any loose connections or damaged components. If you find any signs of wear or damage, it’s crucial to seek the advice of a qualified electrician to resolve the issues promptly.

Check your appliances : Faulty appliances can often cause your RCD to trip. Ensure you unplug and inspect them periodically for any frayed cables, loose plugs or damaged pins. If you notice any issues, seek professional help or replace the appliance as required.

Test your RCD : To make sure your RCD is working correctly, perform the “test button” procedure every three months. Press the test button on your RCD, and it should trip immediately. If it doesn’t, call a qualified electrician immediately to resolve any issues with your unit.

Avoid overloading sockets : Avoid plugging too many devices into a single socket or using multiple power strips, as this can cause an overload and trigger your RCD to trip. Distribute your electrical load evenly across the sockets in your home to help prevent overloading.

Be mindful of moisture and dampness : Moisture build-up can cause RCD trips in damp environments. Keep an eye out for water ingress or dampness around your sockets, lights and appliances. Fix any leaking pipes, address any condensation issues and maintain adequate ventilation to avoid moisture build-up.

Following these tips and regularly checking your electrical system can significantly reduce the likelihood of RCD tripping in your home. Remember, if you encounter any issues or are unsure about any aspects of your electrical system, it’s always best to consult a professional electrician for assistance.

Similar Posts

CFL Lamps: What are they and why they are being phased out

CFL Lamps: What are they and why they are being phased out

Compact Fluorescent Lamps (CFLs) have been a versatile lighting option for many years, particularly in commercial applications. They come in various types to accommodate specific needs and have been a popular choice due to their energy efficiency and long life. However, changes in legislation and advancements in lighting technology have led to the phasing out…

How Much Electricity Does a Fridge & Freezer Use?

How Much Electricity Does a Fridge & Freezer Use?

Refrigerators and freezers are essential appliances in our daily lives, helping us preserve our favourite foods and reduce waste. Knowing the electricity consumption of these appliances is crucial for understanding their impact on our energy bills and the environment. Not only do they consume power during regular use, but factors such as energy efficiency ratings,…

What Fuse Do I Use in a Plug?

What Fuse Do I Use in a Plug?

Fuses are an essential element of safety in electrical appliances and systems. Their job is to protect users and equipment from power surges, ‘blowing’ when they detect an excess of electricity. The fuse in a plug is there to protect the connecting power lead from such power surges.  For standard UK plugs, i.e. BS1362 plugs,…

The Dangers of Flickering LED Lights

The Dangers of Flickering LED Lights

Flickering LED lights may seem like a minor issue but, if left unchecked, can pose several dangers and lead to negative health effects. Although a sudden flicker might not be inherently harmful, continuous and regular flickering can impact not only an individual’s health but the performance of electronic devices as well. Understanding the causes of…

How do Kinetic Switches work?

How do Kinetic Switches work?

Kinetic switches have garnered much interest in recent years due to their innovative technology and energy-saving capabilities. As the name implies, kinetic switches operate using kinetic energy—energy derived from motion. This unique characteristic makes them an attractive alternative to traditional electrical switches, offering various applications and benefits for both residential and commercial usage. To better…

No Power to Boiler? What to Check

No Power to Boiler? What to Check

Few things are more frustrating than having a broken-down boiler with no power. There are several potential issues that may leave you with no power to your boiler; the problem could lie with either the boiler itself or further down the electrical supply chain.  The most common reasons behind having no power to your boiler…

MR AMP

What is the purpose of a Trip Switch?

Understanding the trip switch: a guide to electrical safety.

The trip switch, often referred to as a circuit breaker or residual-current device (RCD), plays a crucial role in safeguarding our homes and businesses from electrical hazards. This essential component monitors the flow of electricity within a circuit and automatically cuts off power when it detects a fault, such as an overload or a short circuit. In this blog post, we’ll delve into the importance of trip switches, how they work, and why they are a fundamental aspect of electrical safety.

What is a Trip Switch?

A trip switch is a safety device designed to protect electrical circuits from overloads, faults, and other electrical issues that could pose a risk to property and personal safety. When an abnormal electrical condition is detected, such as a surge in current or a ground fault, the trip switch immediately interrupts the circuit to prevent potential damage to appliances, wiring, and the risk of fire or electric shock.

How Does a Trip Switch Work?

The basic principle behind a trip switch is simple yet effective. It continuously monitors the electrical current flowing through a circuit. If the current exceeds a predetermined threshold or deviates from its normal path, indicating a fault, the trip switch quickly triggers a mechanism to cut off the power supply. This rapid response helps to minimize the risk of electrical fires, equipment damage, and personal injury.

Why is a Trip Switch Important?

Ensuring the proper functioning and maintenance of trip switches is crucial for electrical safety in both residential and commercial settings. A malfunctioning or outdated trip switch can fail to respond to electrical faults, leaving your property vulnerable to potential hazards. Regular inspections, testing, and timely replacement of trip switches are essential to ensure they are functioning correctly and providing reliable protection against electrical faults.

In conclusion, the trip switch is a vital component of modern electrical systems, serving as a first line of defense against electrical hazards. By continuously monitoring and interrupting abnormal electrical conditions, trip switches play a pivotal role in safeguarding our homes, businesses, and loved ones. Regular maintenance and proactive monitoring of trip switches are key to ensuring their effectiveness and maintaining a safe and secure electrical environment. If you have concerns about your trip switch or need professional assistance with electrical safety measures, don’t hesitate to contact MR AMP. Our team of experienced electricians is here to help you with all your electrical needs and ensure the safety and reliability of your electrical systems.

Diamond Certified

  • Our History: Lighting the Way Since the Turn of the Century
  • Our Partners
  • Career Opportunities
  • Certifications and Accreditation
  • Residential Electrical Services
  • Commercial Electrical Services
  • Industrial Electrical Services
  • Client Showcase
  • Information and Tips
  • Featured Products
  • In The News
  • Estimating LED Lumens for Your Space
  • Testimonials
  • Fixing a Sensitive Arc-Fault Circuit Breaker

Posted on Wednesday, March 13th, 2019 at 5:34 pm

Roberts Electric arc fault circuit interrupter

Causes for the electrical interruption may include:

  • An overload–when electrical usage would have begun to overheat a circuit’s wires.
  • A short circuit–very high current resulting from a fault on the circuit.
  • An overheating breaker– when the breaker itself has poor contacts or connections.
  • A ground-fault–smaller leakage off of the intended circuit. In this I include shock hazards, neutral to ground faults, and the differing current on the neutral wire when it is being shared by another circuit.
  • An arc-fault–sparking happening on the circuit or its lights or appliances.

Most of the time you can find the cause and correct the problem without having to call an electrician.

Tips for troubleshooting an arc-fault interrupter

  • Don’t confuse AFCIs with ground-fault circuit interrupters (GFCIs), which are designed to protect against shocks (not arcs). To tell whether immediate tripping is from a ground-fault versus a short circuit, you might have to temporarily replace the AFCI breaker with a standard breaker (putting the solid white wire from the AFCI’s terminal into the panel’s neutral/ground bar). If the standard breaker holds, then the problem is more likely to be a ground-fault than an arc-fault.
  • In the case of an arc-fault device introduced into an existing home, a common cause of tripping will be that the neutral of the circuit is mixed somewhere with the neutral of another circuit. The two common places this mixing of neutrals would occur are at a 2-gang or 3-gang switch box where both circuits are present, or in a 3-way switch system where the neutral for the light(s) has been borrowed (improperly) from the other circuit.
  • As long as you do not leave it in place beyond your troubleshooting, a standard breaker could be put in the panel in place of the AFCI. You might then be able to hear, see, or smell signs of heat or arcing. Blinking lights on the circuit would give additional clues.
  • In most homes (most don’t have AFCIs), when arcing at connection points has been happening for a while, it commonly shows itself as a partial outage of the circuit, from the arcing point on.
  • Some appliance models have been known to trip an AFCI by their sensitivity to either arcing (in flat-screen TVs, vacuums, other appliances with motors) or to ground-faults (in treadmill, fluorescent lights).
  • If this doesn’t solve the problem, hire an electrician to install a new arc-fault breaker in the electrical panel. If the nuisance tripping stops, then the old arc-fault breaker was probably defective.
  • If the arc-fault breaker still trips, the electrician then needs to track down the cause by going into each switch, receptacle and light box to look for a wiring problem. Wires are often folded (jammed) into boxes quickly, and if the wrong two wires make contact, they can trip an AFCI.

According to 2014 code, anyone, including homeowners, replacing a receptacle in most rooms of a house will be required to make it arc-fault protected.

Need to call an electrician?

If your arc-fault circuit interruption is not responding to your troubleshooting efforts and it’s time to call an electrician, contact Roberts Electric . Our residential team is skilled at troubleshooting and fixing electrical problems.

Recent Posts

  • Roberts Electric: Diamond Certified for 17 Straight Years
  • Saving Energy with LED Holiday Lights
  • Time for Your Own Charging Station for Your Electric Car?
  • ENERGY STAR: Save Money, Save the Environment
  • Tips for a Functional, Energy-Efficient Home Lighting Design
  • Fire Season Safety with Enhanced Smoke Detectors
  • Convert to LED: Save Money, Save the Environment!
  • Employee Highlight: Chris Riley
  • Family Room Remodel for Berkeley Architect
  • Call Us: 510-834-6161
  • ©2024 Roberts Electric Company (RECO)
  • Bonded and Licensed - CA Lic #728215
  • All Worker's Compensation and Liability Insured

Roberts Electric (RECO) is proud to be Diamond Certified for 23 straight years. Roberts Electric is also a member of the National Association of the Remodeling Industry (NARI) and accredited by the Better Business Bureau .

To schedule an appointment or to arrange for service, please see our service area and request a quote here, or call 510-834-6161 .

  • Privacy Policy

DIYnot Forums

  • Search forums

Follow along with the video below to see how to install our site as a web app on your home screen.

Note: This feature may not be available in some browsers.

  • Electrics UK

RCD Trip switch too sensitive

  • Thread starter Cornish Maid
  • Start date 30 Apr 2011

Spark123

ericmark said: The trips do come with variable sensitivity and time delays but to protect people it has to be 30mA @ 40ms so that option is not open to you. Click to expand...

ericmark

Spark123 said: ericmark said: The trips do come with variable sensitivity and time delays but to protect people it has to be 30mA @ 40ms so that option is not open to you. Click to expand...

SwindonSpark

I will try to get a photo up later, but for the meantime, details from the trip unit are: Crabtree 854293 RCCB 80A 30mA List No: 380/030 If that means anything to anyone. Click to expand...

DIYnot Local

If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.

Select the supplier or trade you require, enter your location to begin your search.

Are you a trade or supplier? You can create your listing free at DIYnot Local

Similar threads

  • 12 Mar 2007

ban-all-sheds

  • 29 Feb 2020
  • 19 Sep 2007

trip switch too sensitive

What to do if your fuse box trips

trip switch too sensitive

Has your fuse box tripped? This could be happening for several reasons but usually, there’s an easy fix. Through a process of elimination, you will be able to work out what’s causing the problem and reset the trip switch yourself.

Don’t be left in the dark! Learn the simple steps below and you’ll never be stuck searching for candles when the lights go out again. Our quick guide will equip you with the knowledge you need to fix your fuse box in seconds.

However, please remember that while it is perfectly safe to touch your fuse box, faulty electrics are very dangerous. If you are not confident in your ability to carry out electrical tasks, always seek the help of a qualified electrician.

How does a fuse work?

Before we explain what to do if your  fuse box  trips, let’s quickly go over the purpose of a fuse. We’re sure you already know but a refresher never hurts right?

Fuses are important components, used in electric circuits as a safety measure. If there is a fault in the electrics or excessive current flow, the fuse will heat up and melt. This will break the circuit, ensuring both you and those living in your home remain safe.

Although some older properties still have traditional fuse boxes with fuse wire, today you’re more likely to have a modern fuse box installed. This will contain trip switches or circuit breakers. The advantage of having a modern fuse box is that you will not have to replace the fuse wire, every time it blows. If your fuse box trips, it’s a matter of flicking a fuse switch to reset it, which is far more convenient.

Locating your fuse box

It’s important to know where your fuse box is located, as you never know when you may need to turn the electricity off in an emergency. It should be installed in an easily accessible place so that you can locate it, even if the lights go out.

Your fuse box will contain three types of components:

  • The main switch – Turns off the electricity supply to your home. Useful in an emergency.
  • Fuse switches (or circuit breakers) – Switches that trip to protect the appliances in your home, if there’s a fault in the circuit. They provide more accurate protection than traditional wire fuses.
  • RCDs (Residual Current Devices) – Switches that will trip and turn off the electricity if the circuit they manage is considered dangerous. They are designed to prevent electrical fires and electrocution.

Dealing with a tripped fuse switch

If your appliances have stopped working or your lights have gone out all of a sudden, you’ve likely  tripped a fuse switch . To resolve the problem, you’ll need to locate the main fuse box in your home and check to see if all of the trip switches are on.

Not sure whether ‘on’ means fuse box switches up or down? See if the majority are up or down and you’ll have your answer. It’s most likely to be the up position for ‘on’ and the down position if they’ve tripped.

If any switches are down, move them back into the up position to turn them back on. If it doesn’t appear to be an electric trip switch that has moved, it’s probably one of your RCD switches. Make sure they’re turned on too. Once this is done, everything should be back in working order.

Just to recap:

  • Locate your fuse box and lift the cover
  • See if all of the trip switches are on
  • Switch any on that have tripped
  • Check the RCD switches are on too

Why has my fuse box tripped?

If you’re lucky, your electric fuse box will have little labels under each switch telling you which circuit they manage e.g. lights, shower, sockets. This makes it much easier to identify where the problem is located and will save you having to turn off every light and unplug every device in your home to work out what’s tripping.

As a rule of thumb, the last appliance or light fixture you used is likely to be the cause. Trip switches are very sensitive so as soon as there’s an issue, they’ll kick into action.

If your box isn’t labelled or you can’t narrow down the problem, the only solution is to unplug every device in your home, reset the switch and plug them back in one at a time. It’s time-consuming but should find the root of your problem.

Overloading circuits

If all of your appliances are in good working order, they’re unlikely to affect your trip switch. Instead, it could be down to you overloading your circuits. By this we mean, using too many electrical appliances at one time. If you’re boiling your kettle, using your toaster, charging your phone, watching TV and running your dishwasher all on one circuit, you could be overloading it, resulting in your electricity not working the way it should.

Your electric fuse box won’t like you overloading your circuits, as it’s potentially dangerous. Stop it tripping by checking you don’t have too many appliances plugged into the same socket.

Why won’t the trip switch reset?

If you have attempted to reset your fuse switch but it keeps tripping, it’s likely there’s a problem with one of your appliances or sockets. To determine this:

  • Unplug all of your appliances and try resetting the fuse switch.
  • Once reset, plug your appliances back in one at a time and switch them back on.
  • If the switch trips again, you’ll know it’s the last appliance that you plugged in and switched on.
  • Turn off and unplug the appliance, before resetting the switch.
  • Do not attempt to plug the appliance back in – it’s likely there’s a fault with its wiring that will need replacing.

You don’t necessarily need to throw the appliance away – the issue could be easy to fix. However, faulty appliances can be dangerous, so it’s best to get in contact with an experienced electrician.

Why has the main fuse tripped again?

Although there’s usually a simple explanation of why your circuit breakers or RCDs are tripping, if it’s the main switch, it can be a little more complex. It could mean there’s a problem with the fuse box itself. If this is the case, you’ll need assistance from a qualified electrician. We do not recommend tampering with your fuse box yourself.

Get assistance quickly and avoid expensive call-out charges by taking out a home cover policy for your fuse box.

Rather leave it to the experts?

Fuse box tripped and unsure how to fix it? You’ll greatly benefit from taking out comprehensive home cover. Hometree offer  home care plans  you can trust, with quick and convenient call-outs and a 24/7 UK helpline. What’s more, we don’t put caps on claims and if you don’t claim, your price will always stay the same!

You may also like

trip switch too sensitive

Battle of the smart thermostats – vSMART vs Wave

The battle of the thermostats returns! This time it’s a face-off between the Worcester Wave and the Vaillant vSMART, with their ability to intelligently control your heating over your internet connection. Both smart thermostats allow you to fine-tune your central heating and hot water whether you’re at home or on the go to be better suit your lifestyle. Worcester and Vaillant are the UK’s top boiler manufacturers but how do their smart thermostats compare?

trip switch too sensitive

Vaillant ecoTec Plus 938 Storage Combi Boiler – Review

Vaillant’s ecoTec Plus 938 is a popular choice for those with mid-sized properties. Founded in Germany in 1874, Vaillant is Europe’s second largest boiler manufacturer, while directly competing with Worcester Bosch. High quality and polished German-engineered energy products all sit within Vaillant’s product lines.

trip switch too sensitive

What is Boiler Insurance?

There’s nothing worse than being left with no central heating or hot water due to a broken boiler. Boiler breakdowns can happen at any time – often at the worst of times, like in the middle of winter – and they usually do! Standard home insurance policies and manufacturer warranties tend to only provide limited protection.

We Beat or Match Any Quote

Call 0330 912 4843 and we’ll beat or match any quote.

Serious About Service

24/7 claims support & rated Excellent on Trustpilot

Cover Match Guarantee

Get a £50 gift card if you find something we don’t cover

All Gas Boilers Covered

All makes and models, regardless of age

Privacy Overview

Set your location

To see trades in your area, please set your location below.

Set your location for available services...

Your location is

Why does my safety switch keep tripping?

As irritating as a tripping safety switch may be, it is only doing the job it is designed to do! As a safety switch is designed to shield people from an electric shock, if it has tripped that usually means there is a problem somewhere that needs to be addressed. This is usually a leaking current or a faulty appliance, so it is important to get to the bottom of the problem. It is all sorts of frustrating when you are sitting in the dark and your neighbours are watching a movie and eating their dinner with the lights on, but remember a safety switch is an important safety mechanism for possible electrical leakages in your home!

Safety Switch

What happens when my safety switch trips?

When a safety switch or RCD ‘trips’, the power to that circuit is almost instantly cut off to ensure no harm comes to the people around that particular circuitry. Remember however that a safety switch is installed only on one particular circuit, therefore if your home or office has more than one circuit then the tripping of one switch may not mean the disconnection of all power.

If your power has gone out, there is a chance that your safety switch has tripped. If this is the case, your safety switch or RCD will likely be in your fuse box or switchboard and, when you find it, if the switch is turned to ‘OFF’ this means it has tripped. Bear in mind however that some new systems will only ‘click off’ halfway, meaning the switch won’t be completely in the ‘OFF’ position. It is therefore really important to properly (and safely) check your safety switch to see what position it is in. If your safety switch or RCD is still turned to ‘ON’, but your power is off, your electrical problem does not lie with your safety switch. If your safety switch is sitting on ‘OFF’ however, you need to figure out safely why it has tripped.

Why is my safety switch tripping?

The reason why a safety switch trips can be a few different things, including (but not limited to) :

  • Damaged wiring, which is mostly caused by wear and tear over time
  • A short-term electrical fault, which is generally easily fixed
  • If you have heavy rainfall, rain damage can occur and you should definitely call an electrician if that happens
  • When too many appliances are running at once, which can cause nuisance tripping
  • RCD sensors can be triggered by electrical storms, lightning and thunder however this usually fixes itself
  • A faulty safety switch (uncommon but can happen!)

Need professional electrical services from a local Master Electrician? We Can Be There Today!

Book online or call 1300 054 488

shutterstock_497967799

Call us now

For all your electrical and plumbing needs, call us on  1300 054 488 .

What do I do if my safety switch keeps tripping?

If your safety switch is tripping, there are a few different ways you can address this. To begin with, it may be as quick and easy as switching your safety switch back to ‘ON’. If you give this a go, and it flips back to ‘OFF’ instantly, then there is another option you can consider… but it can be a little time consuming. It requires you to unplug every single appliance in your home (and we mean every one ) and turn your safety switch to ‘ON’. If it stays on, re-plug your appliances back in, one by one, and you will likely find out which one is the culprit – freezers, irons, fridges, kettles and toasters are the common guilty parties, as well as rangehoods and washing machines.

If you find the appliance causing the tripping, keep it unplugged and ensure a qualified appliance repair technician takes a look at it.

If your safety switch is still remaining on ‘OFF’, or keeps tripping, give a licenced electrician a call and they can assess the problem.

How often should I test my safety switch?

It is recommended that you test your safety switch /RCD every month to make sure it is still working properly. To check performance, press the test button on the switch and it will trip the power and then reset by returning the switch to ‘ON’. If it doesn’t trip, contact us immediately as there is likely an issue with your safety switch or RCD.

If you would like to know some more information regarding safety switches and their installation in your home, give us a call on 1300 762 260 or complete an online contact form now.

Licences & Memberships

ARCtick_certified-01

We Can Be There Today!

ElectriciansForums.net | Free Electrical Advice - Electricians Forums: Electricians' Talk Forums

  • Navigation Welcome Forum Electrical Tools Electrical Forum UK USA Australia Canada Electric UFH Advice Lighting & LED CCTV & Security (Public) Electrician Courses Access-Only Training How to Access Training Central Heating Advice DIY Electrical Advice
  • Site Supporters Forum
  • Pro's Only Electricians Arms How to Access The Arms Industrial Electricians Wiring, Theories, Regulations Engineering Chat Periodic Testing Problems Electricians Downloads Commercial Electricians Security (Access-Only) Access Private Area Business Related Advice Certification Schemes Electrical & PAT Testing
  • Thread or Forum Controls New posts Search forums

Follow along with the video below to see how to install our site as a web app on your home screen.

Note: This feature may not be available in some browsers.

  • Please checkout the new poll we will be pushing hard, and want some good stories to come out of this result are public - you can change your vote over time, which might genuinely be the case from time to time.
  • Electrical Advice
  • Electrical Advice by Country
  • Electricians' Talk | All Countries

Trip switch tripping inexplicably...

  • Thread starter ChrisR
  • Start date Jan 3, 2008
  • Tags arial canada photos problem supply switch trip tripping

Discuss Trip switch tripping inexplicably... in the Electricians' Talk | All Countries area at ElectriciansForums.net

  • Jan 3, 2008

Working on some home electrics with a peculiar problem which I hope someone might be able to comment upon… Randomly, the trip switch trips…! It’s an old trip switch and fuse box and I’ve been lead to believe that the old style trip switches will eventually trip and not be able to be reset BUT in this case it is simply trips frequently (often overnight but not exclusively so. No apparent pattern, ie. not at the same time or after the same appliance is switched on) so what I’m wondering is whether when they get old these trip switches are also prone to randomly tripping? Don’t want to install a new trip unless it is likely that this is the source of the malfunction because the new unit will have a lower resistance and therefore if this isn’t the source of the problem will potentially trip more frequently. For reference, I have taken a couple of pictures of the fuse box and trip switch for illustration: Fuse box = http://www.flickr.com/photos/7311928@N04/2161458715/ Trip switch = http://www.flickr.com/photos/7311928@N04/2162255542/in/photostream/ Hope someone can suggest something... Thanks, Chris  

Taking a guess I would say it needs replacing as it may just be too sensitive now as it is an old unit.  

Are modern trip switches less less sensitive/more intelligent and therefore less prone to this kind of problem? Thanks for your help.  

I don't think it is that so much as they do age - even 'newer' style mcb's need replacing from time to time because of inexplicable tripping.  

  • Jan 4, 2008

but it is realistic that the trip switch is the cause of the problem...? Thanks,  

  • Jan 5, 2008

looks like an old ELCB (earth leakage circuit breaker). I used to work on VOELCB's (voltage operated) they were dreadful. Cant quite see what the IDeltaN trip current is on your trip. i have seen them as high as 500mA on old ones. Have you considered that there might actually be a problem on your circuits? Have you tested it at all? What supply system have you got? is it TT, TNCS to TNS? Is the ELCB protecting the whole board? If so, and its a TT you would need to replace it with a 100mA RCD and then put a 30mA on the required circuits (supply to shed, sockets likely to feed equipment outdoors etc) Be usefull to have a bit more info! regards Tony  

Info on the breaker is as follows: Chilton Type 'E' current operated earth leakage circuit breaker Rated tripping current 500mA, 240v, 60A, 50~  

So it is an ELCB! and a 500mA! (damn i'm showing my age now!). i would certainly look to changing this, but be prepared that the ELCB MAY be doing its job (ie detecting a fault). Trying to get the old grey matter working ( and i aint got time to look it up) but i'm pretty sure ELCB's worked on a slightly different principle to RCD's Would need to know the supply to go any further though. Chris, no disrespect, but have you sufficient electrical knowledge to be able to answer the questions? (like what the supply is?) If not I would be happy to help you out on this forum in sorting this out regards Tony  

Hi Tony, No offence taken but you're quite right in guessing that I'm not very clued up about the subject. How do I work out the information you need about the supply? Thanks for your help, Chris  

Tony's your man - lecturer trhrough and through. I could explain but it would take me about 20,000 words when I think Tony will reply in a succinct way!  

Never heard that one about circuit breakers tripping without an explanation.The only apparent reason that such a device would operate would be if it were to be close to its permitted rated value.Have seen this when additional load added to circuits,namely lights when new fittings or extra ones are added.Misuse when resetting the device is also detrimental to the internal workings of the mechanism as a significant amount of heat is transferred across the terminals when excess current is applied even for a fraction of a second. Be sure before resetting or replacing any overcurrent or RCD devices that all circuits are safe to be energized. By the description of the earlier post and by the authors own admission i would advise that only competent persons undertake installation work to this degree.  

  • Jan 6, 2008

Minky, its an ELCB, ie an earth leakage device, its not got overcurrent protection. So its if its tripping its likely to be an earth leakage problem not an overload situation. Ok, to work out the supply: Do you have an earth electrode / earth spike outside? If so its a TT system. Look at your consumer unit and try to follow where the main earth cable goes. If it goes to the metallic outer sheath of the incoming supply the its a TNS. If its joined to the incoming neutral (normally via abox with PME written on it) then its TNCS. Once we know what the supply is we can work out what we need to replace the ELCB with. To be honest because you've got old 3036 fuses i would look at a complete consumer unit change, and listen to Minky's wise words, this is not for the DIYer!! Ok, had a quick look at ELCB's, and yes i was correct in thinking they worked differently to RCd's. The ELCB actually monitors the earth line, and if senses any current in it, it assumes this current must have leaked from the live conductors. They were prone to indiscriminate tripping from voltages appearing on any part of the earthing or bonding system. Oh, and i should add if you do change the consumer unit this is a notifiable work under Part P - just gets better dont it!  

I know I have an earth spike outside so it must be a TT. Earth cable appears to be well attached to it... Moving home this year so whilst wanting to get the problem sorted I don't want to get more work done than necessary! Thanks guys,  

Thought it would be a TT, ELCB's were commonly used on TT systems. Bottom line is you have two options:- ignore the problem, although this may give you problems when trying to sell the house Resolve the problem, which will invlove replacing the existing ELCB and BS3036 fuse board with a new split load board, with a 100mA RCD at the front end and a 30mA RCD protecting outside supplies (if any) and sockets likely to feed equipment outdoors. As i have said, this is notifiable work under Part P, so you will either have to use a sparks registered with a competent persons scheme or pre-notify the work to the council amd do it yourself or use a non ccompetent person scheme sparks. The sparks should give you a Periodic Inspection Report (PIR) with schedules of inspections and test results attatched. Of course, the idea of doing it and NOT telling your local building control is an absolute no-no. i definetly wouldnt do that. Ok it will save you a lot of money, but Part P of the building regulations SAYS you have to tell them. So you have to. Dont you. As i have brought up previously as well, be prepared that if the ELCB is detecting a genuine fault, (and its a 500mA trip) then you will be replacing it with either a 100mA or 30mA trip (depending on which circuit the possible fault is on) the 17th edition is kicking in now, and under that its likely that all of your circuits will be on 30mA RCD's or RCBO's. Either way its a consumer unit change. You can pick them up for 30 quid, but really, its not a job for the untrained guy, plus you have to be able test the circuits, so you you have to have a test meter as well! Sorry it aint better news, but the ELCB aint gonna get 'better' overnight!!  

  • Jan 22, 2008

Thanks for the comprehensive response Tony. Whilst it does sound hopeful that it's just the ELCB which may need replacing I'm wondering what the process is to test all the circuits to actually pinpoint where/what the problem is before spending on work which may not be necessary. I had a guy round who wasn't cheap but didn't seem able to give me any informaiton regarding the cause of the problem... Thoughts? Thanks  

Chris depends if its a circuit or an appliance thats at fault An insulation resistance test would reveal any circuit that has a fault to earth, but that is done with everything unplugged / disconnected. An insulation test on individual applainces MAY show up the problem, but either way, if you havent got an IR tester its irrelevent!!  

ian.settle1

ian.settle1

  • Jan 23, 2008

Chris Looking at the photo of trip is it fitted on Noah's Ark.  

Now come on Ian If it was on Noah's Ark, then we be applying the seperate regulations for marine craft and ships. Although it could be argued that it is argicultural/horticultural? Havent you learned anything on the IET's forums......... regards Tony  

Reply to Trip switch tripping inexplicably... in the Electricians' Talk | All Countries area at ElectriciansForums.net

Similar Threads

  • gingerrubix
  • Feb 29, 2024
  • UK Electrical Forum
  • issue strange tripping
  • Jun 17, 2023
  • DIY Electrical Advice
  • afci checked keeps outlet replaced replacement switches tripping

Megawatt

  • Jul 31, 2022
  • relay switches two-way
  • Dec 29, 2013
  • Commercial Electrical Advice
  • delta fuse switch tripping

Deleted member 72666

  • Jul 24, 2013
  • generator rcd rcd tripping supply switch tripping

OFFICIAL SPONSORS

Electrical Goods - Electrical Tools - Brand Names

YOUR Unread Posts

Rockingit

  • Latest: Rockingit
  • Today at 2:23 AM

ipf

  • Latest: ipf
  • Today at 2:11 AM

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website. For the best site experience please disable your AdBlocker.

Log in or Sign up

You are using an out of date browser. It may not display this or other websites correctly. You should upgrade or use an alternative browser .

MK RCDs, are they 'over' sensitive, why do they trip? :-(

Discussion in ' Electricians' Talk ' started by always_learning , Oct 26, 2005 .

always_learning

always_learning New Member

Hello, please could some one shed some light on this for me? MK 5780s 80A/30mA on split CU, keeps tripping, maybe once a week, for no apparent reason? There is nothing being turned on/off when it trips.... This is the second one I have had fitted, the last sparks replaced it, saying it was faulty. I find it hard to beleive that this one is u/s too...? Question. What exactly do these RCDs 'sense' that makes them trip? Are MK known to be more 'sensitive' than others...? Thanks in advance......  

sinewave

sinewave Screwfix Select

Question. What exactly do these RCDs 'sense' that makes them trip? Are MK known to be more 'sensitive' than others...? Thanks in advance...... Exactly the same as any other RCD senses! An imbalance in the phase & neutral lines. Being as your now on your second RCD this would now point to a intermitent fault in the wiring rather than a RCD fault. Is there an Immersion Heater on a timer in the installation? These are always a good place to start on 'mystery trips' when 'nothings being used'!  

Rabbit Rabbit

Rabbit Rabbit New Member

Having fitted dozens of MK Sentry based products plus MCB's and RCD's I have only had problems with ONE new MCB (32A B was u/s). So I dont think there are 'over sensitive'. RCD's (Residual Current Detectors) sense the differential current running within the phase and neutrals relative to cpc and is this deviates by a nominal amount then it trips (where nominal amount is 30mA, 100mA etc.) Test the RCD (0.5X, 1X and 5X and a ramp test) and the results are.....(over to you)  
Sinewave, wow, that was quick... No..., no immersions, no timers, all I could think of was the fridge / freezer kicking in... ? just out of interest, what does cpc stand for...? Thanks  

chelski spark

chelski spark New Member

It may be a good idea if you have all your appliances P A Tested.  
Thanks, but 'PA' testing, what is that? Apart from a fridge / freezer, there was nothing else plugged in, apart from a PC.....? I remember reading something about LCD screens leaking to earth, is that correct?  
Excuse me for asking but how do you now that nothing is being turned on and off? As in fridges, freezer, boilers etc all turn themselves 'on and off' so you cant know for sure. My money is on a a failing appliance and one with a heating element(s) within it. No way is it the RCD.  
Just read you comment about there 'only' being a PC. Ageing PC's that use switch mode PSU's are a prime source of such tripping....the list in endless m8. Remove them one by one until RCD trips no more then start reconnecting to ascertain - lots of coffee and an all day job.  
Thanks, but 'PA' testing, what is that ? Apart from a fridge / freezer, there was nothing else plugged in, apart from a PC.....? I remember reading something about LCD screens leaking to earth, is that correct? P A Testing = portable appliance testing  

Sparky Dan

Sparky Dan New Member

When you have time, turn absolutely everything off and then back on one at a time. You may be lucky and find the fault but note that it may be a number of leaking appliances. Failing this you could then IR test the cabling, It could be heat or rodent damage.  

sparkin!

sparkin! New Member

Sinewave, wow, that was quick... No..., no immersions, no timers, all I could think of was the fridge / freezer kicking in... ? just out of interest, what does cpc stand for...? Thanks REMEMBER he is travelling at 50 cycles per/second!lol  
.... Not a problem. I was in the kitchen when the RCD tripped, gas cooker, no TV, no immersion, no radio, day time, no lights on, no washing m/c on, nothing doing in the house, apart from the fridge/freezer, and the pc in the lounge... I agree, it is very unlikely to be the RCD, but as the electrician seems keen to blame the RCD and charge for a new one, I am trying to find the 'real' cause of the problem, or at least eliminate some red herrings..... thanks  
Re: MK RCDs, are they 'over' sensitive, why do they trip? Posted: Oct 26, 2005 8:47 PM Reply Having fitted dozens of MK Sentry based products plus MCB's and RCD's I have only had problems with ONE new MCB (32A B was u/s). So I dont think there are 'over sensitive'. RCD's (Residual Current Detectors) sense the differential current running within the phase and neutrals relative to cpc and is this deviates by a nominal amount then it trips (where nominal amount is 30mA, 100mA etc.) Test the RCD (0.5X, 1X and 5X and a ramp test) and the results are.....(over to you) WHAT IF no access to this equipment? WHAT, would you do MR.CARROT!  
Rabbit_rabbit, with regard to your comment about the PC psu, i understand that they can 'leak', if that is the correct term, to earth? Is there a way round this, or is it new PSU time...? thanks for your help btw  

2wires2many

2wires2many New Member

Water in the base of a cordless kettle is always a favourite on RCD intermittent faults. Kettle is off but base is usually switched on at the socket all the time. I have known this happen more than once, so its well worth checking out. Regards SMc  
Stupid comment. And so ends another sensible thread.....I can see Scroofix closing this forum down due to lack of interest...  
I thought it was a sensible suggestion  
OK,rr get the lettuce out and chill!  
2wires, now that idea sounds plausible, to me anyway... I will have a look to see if the kettle base was plugged in... What i was trying to discover by my original post is: what it is that the (any brand) RCDs detect, so that i can track down the fault (intermittent)....? I have tried the unplug everything and plug everything in, appliance by appliance route, didn't do anything! thanks  
Interesting missing posts hey - clearly Admin are hot tonight.... Many PC's use switch mode PSU's and these tend to have a virtual earth - back-to-back capacitors between phase and neutral the ecentre being conecetd to true earth (cpc). High currents can flow into this virtual earth and hence to the cpc and this in turn can cause imbalances in phase and neutral currents as perceived by the RCD and so it trips. This current is usually quite low for a single PC (less that RCD trip current) but a failing switch mode may be the cause. Having said all that my money is on a freezer, a fridge, an oven, heatre of some kind...  

Share This Page

  • Log in with Facebook
  • No, create an account now.
  • Yes, my password is:
  • Forgot your password?

Screwfix Community Forum

  • Search titles only

Separate names with a comma.

  • Search this thread only
  • Display results as threads

Useful Searches

  • Recent Posts
  • This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register. By continuing to use this site, you are consenting to our use of cookies. Accept Learn More... Dismiss Notice

Get to us….

1810 W. Winton Avenue Hayward, CA 94545-1232

Phone: (800) 458-9600

Fax: (510) 785-1668

Email: [email protected]

Web: D&F Liquidators

D & F Liquidators

  • 5 Reasons Why Safety Switches Trip/Go Off
  • Uncategorized

An electrical guy inspecting safety switch

Safety switches are devices that monitor the movement of current through electrical wiring and disconnect the supply of electricity upon detecting differences or imbalances. They react to even the tiniest change within a fraction of a second, cutting off the power if there’s a leak of electricity to ground, a power board is overloaded, etc.

Unlike surge protectors and circuit breakers (which protect electrical appliances), these devices are designed to shield people from electrocution and fire. Single-phase safety switches and three-phase safety switches find many applications in the electrical industry, especially for residential, business, and commercial switchboards.

What Causes Safety Switches to Keep Going Off?

If the amount of current flowing in matches the current flowing out, safety switches remain on and power supply is uninterrupted. If they keep tripping or going off, however, check for these 5 main culprits:

Faulty/Damaged Appliances

Damaged wiring, nuisance tripping, bad weather, defective switches, how to test your safety switch.

How Often Should Safety Switches Be Tested?

Ideally, it’s a good idea to test safety switches once a month. However, since you only see them when you examine the switchboard, this may be impractical for some people. At the very least, test them once every three months or call a qualified electrician to set up a maintenance and inspection schedule.

D&F Liquidators can provide you with a wide range of electrical components, including NEMA rating switches, insulated wiring and cables, power point terminals and more, at very competitive prices. Contact us to discuss your requirements today!

DFLIQ logo

D&F Liquidators has been serving the electrical construction materials needs for more than 30 years. It is an international clearinghouse, with 180,000 square facility located in Hayward, California. It keeps an extensive inventory of electrical connectors, conduit fitting, circuit breakers, junction boxes, wire cable, safety switches etc. It procures its electrical materials supplies from top-notch companies across the globe. The Company also keeps an extensive inventory of electrical explosion proof products and modern electrical lighting solutions. As it buys materials in bulk, D&F is in a unique position to offer a competitive pricing structure. Besides, it is able to meet the most discerning demands and ship material on the same day.

Share This Story, Choose Your Platform!

Related posts.

Picture of different wires of different sizes

A Simple Guide to Understand Wire Gauge Chart

Picture of a generator

How to Connect Generator to House Without Transfer Switch

Picture of a hand holding a bunch of wires

Types of Electrical Wiring – Everything You Need to Know

Picture of a wire caught fire while plugged into an outlet

What is Short Circuit? (Causes, Signs and Prevention)

Picture of a GFCI outlet

GFCI Outlet Keeps Tripping (How to Fix it)

circuit breaker tripped with a burn mark

trip switch too sensitive

  • Search forums
  • Active Forums
  • General Electrical Forum

Leviton GFCI nuisance tripping and circuit analysis

  • Thread starter tersh
  • Start date Jan 7, 2019

trip switch too sensitive

Senior Member

  • Jan 7, 2019

trip switch too sensitive

190106-2516 EST tersh: I have expressed an opinion on this before. Look at the board layout. There is a long trace from where C3 is located to the SCR gate. I suspect that transient capacitive coupling to the SCR gate is the cause. Try putting C3 directly at the SCR gate, and a 100 ohm carbon comp resistor in place of the trace. This creates a low pass filter at the gate input and also reduces the capacitive coupling to the gate. I think that inductive kick at either turn on or off is the source of the transient. .  

gar said: 190106-2516 EST tersh: I have expressed an opinion on this before. Look at the board layout. There is a long trace from where C3 is located to the SCR gate. I suspect that transient capacitive coupling to the SCR gate is the cause. Try putting C3 directly at the SCR gate, and a 100 ohm carbon comp resistor in place of the trace. This creates a low pass filter at the gate input and also reduces the capacitive coupling to the gate. I think that inductive kick at either turn on or off is the source of the transient. . Click to expand...

LarryFine

Master Electrician Electric Contractor Richmond VA

tersh said: So what part do you think is tripping the circuit? Click to expand...

kwired

Electron manager

I don't generally use Leviton GFCI's so don't know how prone they are to such trips. I do agree that it is likely inductive kickback that is causing the problem if you know there is no ground faults going on, probably happens either when turning on or turning off the appliance?  

190107-1719 EST tersh: I am talking about capacitive coupling within the GFCI device. Thus, the length of wire from the GFCI to the load is not a big factor other than how that affects the voltage transient level when it gets to the GFCI device. The suggestion I was making relative to the GFCI circuit board is to put the shunt capacitor directly at the gate-cathode of the SCR instead of about 1" away. And the series resistor ln combination with the shunt capacitor to the gate is to reduce transient voltage at the gate. .  

gar said: 190107-1719 EST tersh: I am talking about capacitive coupling within the GFCI device. Thus, the length of wire from the GFCI to the load is not a big factor other than how that affects the voltage transient level when it gets to the GFCI device. The suggestion I was making relative to the GFCI circuit board is to put the shunt capacitor directly at the gate-cathode of the SCR instead of about 1" away. And the series resistor ln combination with the shunt capacitor to the gate is to reduce transient voltage at the gate. . Click to expand...

mopowr steve

mopowr steve

As far as issues with refrigerators, The circulation fan in the freezer section behind the back panel is a shaded pole just like the ones used in exhaust fans. So one could expect the same results at turn on and shut off. Unless the problem had anything to do with defrost element issues or erratic compressor issues. My experience with the Leviton GFCI receptacle was primarily when the shaded pole motor was shut off. Because often times a customer would leave the bathroom, turn fan off, and upon returning the GFCI would be in the tripped position.  

mopowr steve said: As far as issues with refrigerators, The circulation fan in the freezer section behind the back panel is a shaded pole just like the ones used in exhaust fans. So one could expect the same results at turn on and shut off. Unless the problem had anything to do with defrost element issues or erratic compressor issues. My experience with the Leviton GFCI receptacle was primarily when the shaded pole motor was shut off. Because often times a customer would leave the bathroom, turn fan off, and upon returning the GFCI would be in the tripped position. Click to expand...

If memory serves me right, I believe it runs at minimum whenever the compressor is running, if it runs constantly it may shut off durring defrost cycle.  

ELA

Electric Fast Transient Testing Electric Fast Transient Testing Historically GFCIs have nuisance tripped due to the Electric Fast Transient generated when fan motors were shut off ( inductive kick ). Many electronic devices are susceptible to failure when exposed to repeatable Electric Fast Transients - at varying amplitude and repetition rates - as set at the Test Generator. I used to have access to a number of EMC test equipments including an EFT Generator. No problem screwing up a lot of electronics when exposed at certain rates and amplitudes. European markets require equipment to pass EMC testing, including EFT testing, in order to be CE marked. We performed pre-compliance EMC testing. The EFT generator can force a GFCI to nuisance trip at a very high repeatably rate as opposed to the random EFT transient generated by a motor turn off.  

ELA said: Historically GFCIs have nuisance tripped due to the Electric Fast Transient generated when fan motors were shut off ( inductive kick ). Many electronic devices are susceptible to failure when exposed to repeatable Electric Fast Transients - at varying amplitude and repetition rates - as set at the Test Generator. I used to have access to a number of EMC test equipments including an EFT Generator. No problem screwing up a lot of electronics when exposed at certain rates and amplitudes. European markets require equipment to pass EMC testing, including EFT testing, in order to be CE marked. We performed pre-compliance EMC testing. The EFT generator can force a GFCI to nuisance trip at a very high repeatably rate as opposed to the random EFT transient generated by a motor turn off. Click to expand...

junkhound

  • Jan 8, 2019

my bet would be that the turn on or turn off transients occasionally series resonate thru the 1:200 CT secondary with C1 to fake the input of the chip into seeing an output of the first CT. The SCR input has a 4.7k to ground inside the chip (plus theexternal gate cap), so it would take a big transient to directly trip the SCR. PS: side experiment for those with the time /g Regular switch (not a snap action switch) being opened and closed at fast and slow rates- which will trip the gfci? Also try with snap action switch or electronic switch, results should be consistent (either nearly always trip or not trip)  

junkhound said: my bet would be that the turn on or turn off transients occasionally series resonate thru the 1:200 CT secondary with C1 to fake the input of the chip into seeing an output of the first CT. The SCR input has a 4.7k to ground inside the chip (plus theexternal gate cap), so it would take a big transient to directly trip the SCR. PS: side experiment for those with the time /g Regular switch (not a snap action switch) being opened and closed at fast and slow rates- which will trip the gfci? Also try with snap action switch or electronic switch, results should be consistent (either nearly always trip or not trip) Click to expand...
tersh said: Here is another clue. If I connect the shaded pole motor to a Siemens GCFI breaker (which doesn't trip) in series to the Leviton based GFCI. Both won't trip. How come putting the Siemens GFCI breaker between the shaded pole motor and the Leviton based GFCI outlet won't trip the latter? If only the shaded pole motor and Leviton based GFCI is connected, the latter trips 80% or 90% of the time or so consistently (like 4 trips for every 5 switchings). Click to expand...

Btw.. for loads like washing machine which doesn't trip the Leviton based GFCI outlets, is there nothing wrong by connecting two GFCI in series for backup in case one fails? I plan to put the 240v GFCI receptacles (which doesn't have auto-monitoring self test mentioned in UL 2015) near wet areas but at the same time the breaker that would protect them would be the Siemens 2-pole GFCI breakers (240v) with auto-monitoring self test mentioned in UL 2015. Both trip at 5mA. The problem with GFCIs is if they become defective (the relays for example). It will remain energized and you won't know it doesn't work anymore. So the GFCI receptacles would be the backup in case the Siemens breakers fail. Or vice versa. ​  

ptonsparky

tersh said: Btw.. for loads like washing machine which doesn't trip the Leviton based GFCI outlets, is there nothing wrong by connecting two GFCI in series for backup in case one fails? I plan to put the 240v GFCI receptacles (which doesn't have auto-monitoring self test mentioned in UL 2015) near wet areas but at the same time the breaker that would protect them would be the Siemens 2-pole GFCI breakers (240v) with auto-monitoring self test mentioned in UL 2015. Both trip at 5mA. The problem with GFCIs is if they become defective (the relays for example). It will remain energized and you won't know it doesn't work anymore. So the GFCI receptacles would be the backup in case the Siemens breakers fail. Or vice versa. ​ Click to expand...
tersh said: Does this occur constantly when the shaded pole motor was shut off? My experience is once for every two tries (or more) or 50% (or 75%) of the time. How about your experiences? Click to expand...

Ukraine war latest: Russian forces take control of village in Kharkiv region - defence ministry

Russian troops are continuing to advance in the Kharkiv region - with the defence ministry claiming it had taken control of 12 settlements in a week.

Sunday 19 May 2024 00:10, UK

Please use Chrome browser for a more accessible video player

  • Russia takes control of village in Kharkiv - defence ministry
  • Ukraine's divisive draft law comes into force | At least 30 Ukrainians have died crossing river to avoid
  • Putin concludes trip to China with veiled reference to West
  • Two civilians killed while evacuating city
  • Analysis: Great power politics on display in China visit
  • Live reporting by  Jess Sharp  and (earlier)  Josephine Franks

We're pausing our coverage of the Ukraine war for the moment.

Scroll through the blog below to catch up on today's developments.

A decorated Ukrainian pilot has been killed in action, the country's 831st tactical aviation brigade has announced. 

In a post on Facebook, the brigade said First Deputy Commander of the Aviation Squadron Lieutenant Colonel Denis Vasilyuk, was killed during a combat mission.

"We lost not just a pilot, but a reliable combat brother, a friend and just a wonderful and bright man," it added. 

He flew dozens of missions since the beginning of the war has has been awarded the Order For Courage medal. 

The medal is handed to members of the military for individual courage and heroism while rescuing people or valued materials while endangering their own life. 

A Ukrainian missile has been destroyed over Belgorod, the Russian defence ministry has said. 

It said the Tochka-U tactical missile was launched at around 9.15pm local time (7.15pm UK time). 

"Duty air defence systems destroyed one tactical missile over the territory of the Belgorod region," it added. 

Belgorod has been targeted several times, with attacks increasing in recent weeks. 

Volodymyr Zelenskyy has praised his forces' successes during his nightly address. 

The Ukrainian president said his troops had grown in confidence, particularly in the Kharkiv region. 

However, his message comes after Russia's defence ministry said its forces captured the village of Starytsia in the Kharkiv region earlier today - just eight days after a new Russian push in the area began.

"The occupier is losing its infantry and equipment, a tangible loss, even though, just as in 2022, it was counting on a quick advance on our land," Mr Zelenskyy said, referring to Russia's initial invasion of Ukraine in February of that year.

In the eastern Donetsk region around Chasiv Yar, a city seen as a key target in Russia's campaign, Mr Zelenskyy said Ukrainian forces had repelled a Russian assault. 

"Our soldiers destroyed more than 20 units of the occupier's armoured vehicles," he added.

Russia has claimed to have captured a "very valuable" British-made vehicle from the battlefield. 

In a post on Telegram, the defence ministry said the FV104 Samaritan evacuation vehicle has been taken but needs to be repaired. 

It claimed it was big enough to evacuate four people and carry a crew of two. 

It said it was "very valuable" and could be used as a "rare collection exhibit". 

It shared a video of the vehicle but Sky News has not been able to verify if it is a FV104 Samaritan. 

Five people have been injured in a Russian shelling attack in Kharkiv, the Ukrainian national police has said. 

A 13-year-old girl and 16-year-old boy are among those hurt, it said. 

The Russian military attacked the city at around 30pm, it added, with several hits recorded on residential buildings. 

"As a result of shelling, five civilians were injured, and civilian infrastructure was also damaged," police official Oleksandr Kobylev said. 

"Currently, two minor children are known to have suffered minor injuries. Necessary medical assistance is provided to all victims." 

A Russian attack plane has been shot down, a Ukrainian army brigade has reported. 

The 110th separate brigade said the Su-25 had been destroyed in Donetsk. 

It said it was the fourth Su-25 to have been shot down, adding it will keep issuing "flaming fines" to Russia for crossing into Ukraine. 

"Our sky will become hell for the occupant pilots. Our squad number will be a nightmare for them," it added. 

A Ukrainian sergeant has been stabbed in the hand by a civilian, the country's ground forces has said. 

In a statement posted on Facebook, the army said the attacker was detained and has been charged with attempted murder and obstructing the armed forces. 

The attack took place in the city of Sinelnikove, in the central Dnipro region, earlier today.

"A civilian committed an armed assault with cold weapons (knife) on the sergeant of the Armed Forces of Ukraine," the statement said. 

The sergeant, who worked for the territorial recruitment and social support centre, has been provided with "all the necessary medical care", it added. 

In Ukraine's second largest city, airstrikes have become a daily occurrence as intense battles continue. 

Russian troops have been pushing ahead with a ground offensive that opened a new front in northeastern Kharkiv region in recent days, putting further pressure on Kyiv's overstretched military. 

After weeks of probing, Moscow launched the new push knowing that Ukraine suffered personnel shortages, and that its forces have been spread thin in the northeast.

Two people were killed after Russian airstrikes hit Kharkiv on Friday as Ukrainian troops fought to halt Russian advances in the region.

The airstrikes targeted Ukraine's second-largest city during the daytime, injuring 25 people and killing two, according to Kharkiv's mayor Ihor Terkhov.

On Thursday, the air alarm sounded for more than 16 hours, a record since the beginning of the military campaign by Russia.

Here are some of the latest pictures from the city: 

Ukrainian drone attacks on Russian power facilities in early 2024 disrupted 14% of Russia's oil refining capacity, according to the US Department of Defence.

The strikes pushed up domestic oil prices by 20-30% and forced Russia to halt exports to focus on meeting domestic demand, a report from the Pentagon’s intelligence agency said.

But it caused only a "negligible disruption" to the electricity supply for Russian civilians and the military, because of Russia's "robust generation capacity" and the level of power in the grid. 

Be the first to get Breaking News

Install the Sky News app for free

trip switch too sensitive

COMMENTS

  1. RCD Trip switch too sensitive

    30 Apr 2011. #4. The trips do come with variable sensitivity and time delays but to protect people it has to be 30mA @ 40ms so that option is not open to you. However not all 30mA @ 40ms are the same. Some makes are better than others at resisting spikes. The speck says it must not trip at 15mA and must trip at 30mA.

  2. Fixing a Sensitive Arc Fault Circuit Breaker

    This can create a situation where a circuit breaker keeps tripping without a load. Damage or deterioration to wires or cords also causes arcing faults and will trip the circuit. To prevent this, avoid pushing furniture against plugs in an outlet. Usually, unplugging electrical and electronic devices solves the problem.

  3. Does Your RCD Keep Tripping? Read To Prevent RCD From Tripping

    How to fix faulty appliance from tripping. If you suspect that a faulty appliance may be causing your RCD to trip, try unplugging every electrical appliance in your home and checking whether your RCD resets correctly. If it does, plug in each appliance one by one and reset your RCD as you plug in each item. If suddenly the RCD starts tripping ...

  4. Why Is My RCD Tripping? Troubleshooting

    The heating element is leaking current. Water leak. Faulty drain pump. Damaged wiring. The door safety lock is stuck. The start/stop switch is defective. Worn out motor. All of these points above are worth investigating as one or more of them could be causing your RCD to trip. If your RCD is regularly tripping and you can't immediately see an ...

  5. What to do if your RCD trips

    Trip switches are very sensitive for your safety so as soon as there's an issue, they'll kick into action and cut the power. If your box isn't labelled or you are struggling to narrow down the problem, the only solution is to unplug every device in your home, reset the switch and plug them back in one at a time.

  6. What To Do If Your RCD Keeps Tripping?

    Inspect the circuit breaker panel. One of the first things you should do if your RCD keeps tripping is to inspect the circuit breaker panel. Make sure that all the switches are in the correct position, and that none of the breakers are tripped. If you do find that a breaker is tripped, try to reset it. If the breaker trips again, it could be a ...

  7. RCD tripping and no idea why

    RCD seems to trip randomly and I'm not sure why. It seems to be related to the kitchen sockets and the fridge in some way. Background: A few weeks ago, my electricity kept tripping. When I looked in the consumer unit, the RCD was down, but it wouldn't go back up unless the kitchen switch was down. As it seemed to be tripping at random times of ...

  8. Understanding RCD Tripping: Causes, Fixes, and Prevention

    RCD tripping occurs when the RCD detects a fault in the electrical circuit. This causes the RCD to immediately switch off the power to prevent harm. Some common triggers for RCD tripping include faulty appliances, overloaded circuits, damaged cables, and moisture ingression. While occasional nuisance tripping can occur, repeated RCD tripping ...

  9. What causes nuisance RCD tripping?

    Occasionally, an RCD can trip even when there is no fault to speak of (if there is a great surge in power, for example) but if it's happening regularly then it's most likely due to one of three causes: Faulty equipment - As electrical equipment ages, it can become more unstable, particularly when used in tandem with other devices.

  10. How to Fix RCD Tripping: A Comprehensive Guide for Quick Solutions

    Locate the RCD in your consumer unit and push the test button; this should cause the RCD to trip. To reset, push the switch back to its original position. If the issue persists, move on to the next solution. Fixing Circuit Overlord. A circuit overlord occurs when too many devices draw power from the same circuit simultaneously. To fix this issue:

  11. What Is The Purpose Of A Trip Switch?

    How Does a Trip Switch Work? The basic principle behind a trip switch is simple yet effective. It continuously monitors the electrical current flowing through a circuit. If the current exceeds a predetermined threshold or deviates from its normal path, indicating a fault, the trip switch quickly triggers a mechanism to cut off the power supply.

  12. How can I stop this GFCI receptacle from tripping?

    173 1 1 4. 2. FYI, you can buy an alarm to warn you when the GFCI trips. - Doresoom. Nov 7, 2013 at 17:57. Add a comment. Refrigerators and freezers that are permanently located in the garage and are not movable are not required to be protected by GFI. The outlet may be a single outlet or the outlet may not be readily accessible.

  13. Fixing a Sensitive Arc-Fault Circuit Breaker

    If the arc-fault breaker still trips, the electrician then needs to track down the cause by going into each switch, receptacle and light box to look for a wiring problem. Wires are often folded (jammed) into boxes quickly, and if the wrong two wires make contact, they can trip an AFCI. According to 2014 code, anyone, including homeowners ...

  14. RCD Trip switch too sensitive

    RCD Trip switch too sensitive. Thread starter Cornish Maid; Start date 30 Apr 2011; Prev. 1; 2; First Prev 2 of 2 Go to page. Go. Spark123. Joined 2 Jun 2005 Messages 14,841 Reaction score 477 Location ... I know that the 30mA RCD must trip at both positive and negative cycles at 30mA and at 5 times 30mA it must trip again both half cycles in ...

  15. What Causes GFCI Outlets to Keep Tripping?

    If insulation is old or damaged, its resistance is lower and leakage current could become substantial. GFCI Trips: On GFCI-protected circuits, leakage current can cause unnecessary and intermittent tripping. When many pieces of equipment are operating on a circuit, the leakage current is cumulative and could cause a GFCI to trip randomly.

  16. What to Do if Fuse Box has Tripped

    To determine this: Unplug all of your appliances and try resetting the fuse switch. Once reset, plug your appliances back in one at a time and switch them back on. If the switch trips again, you'll know it's the last appliance that you plugged in and switched on. Turn off and unplug the appliance, before resetting the switch.

  17. trip switch too sensitive

    Trip switch is not faulty! Pump on boiler is faulty and the trip switch is cutting off the power to save you getting a fatal electric shock! get the boiler pump repaired/replaced asap. ... trip switch too sensitive - when pump on gas central heating has been running. Anonymous user 8 November 2014 - 11.32 AM. The trip switch on my fuse box ...

  18. Why does my safety switch keep tripping?

    When too many appliances are running at once, which can cause nuisance tripping; RCD sensors can be triggered by electrical storms, lightning and thunder however this usually fixes itself ... To check performance, press the test button on the switch and it will trip the power and then reset by returning the switch to 'ON'. If it doesn't ...

  19. RCD tripped and will not stay up

    In case it isn't clear, the reason you cannot get the RCD switch to stay up is probably because the fault that 'tripped' it is still there. The process elsien describes is necessary to work out where that fault is and isolate it. The other thing I'd do before anything else is to switch off and unplug any sensitive electrical equipment like ...

  20. Trip switch tripping inexplicably... > on Free Electrical Advice

    ChrisR. Jan 3, 2008. #1. Working on some home electrics with a peculiar problem which I hope someone might be able to comment upon…. Randomly, the trip switch trips…! It's an old trip switch and fuse box and I've been lead to believe that the old style trip switches will eventually trip and not be able to be reset BUT in this case it is ...

  21. MK RCDs, are they 'over' sensitive, why do they trip?

    So I dont think there are 'over sensitive'. RCD's (Residual Current Detectors) sense the differential current running within the phase and neutrals relative to cpc and is this deviates by a nominal amount then it trips (where nominal amount is 30mA, 100mA etc.) Test the RCD (0.5X, 1X and 5X and a ramp test) and the results are..... (over to you)

  22. 5 Reasons Why Safety Switches Trip/Go Off

    If they keep tripping or going off, however, check for these 5 main culprits: Faulty/Damaged Appliances. Old, damaged, or faulty electrical appliances can leak extra current, and safety switches will trip when they detect the excess flow. With heavily used appliances, wear and tear is the main reason for performance issues, so you need to ...

  23. Leviton GFCI nuisance tripping and circuit analysis

    Even if the plug is 2-prong (without any grounding and it's put on glass surface). The Waterpik motor can consistently trip the Fairchild chipset (I tested 4 units and same results). This is used in the Leviton. It doesn't trip on other brands of GFCI such as the Siemens GFCI. It's even when the motor was isolated and not wet (even if rotor ...